<strong>MBQ</strong> <strong>Series</strong><br />

Vertical / Horizontal / <strong>Co</strong>unterflow<br />

<strong>Co</strong>mbo Air Handler<br />

Heat Pump or DX <strong>Co</strong>oling / Hot Water Heating<br />

1-1/2 through 5 tons, up to 91,000 BTUH Heating<br />

Description :<br />

This "combo" air handler converts a properly sized gas or oil-fired water heater into a highly efficient space heating<br />

appliance that can heat your home as well as provide domestic hot water. <strong>Co</strong>mbo space heating is quickly<br />

becoming the most popular heating system for today's educated consumer. <strong>Co</strong>mpared to other heating systems,<br />

combo heaters offer higher efficiency, greater installation flexibility, cost less to install and are much simpler<br />

to service.<br />

Proper water heater sizing is required to insure adequate hot water supply and space heating. <strong>Co</strong>ntact the factory<br />

for sizing information.<br />

Now with 2 - speed Fan Operation!!<br />

(High Speed - <strong>Co</strong>ol, Medium Speed - Heat)<br />

FEATURES:<br />

1. 4-way airflow (kit required for counterflow)<br />

(60<strong>MBQ</strong> not approved for counterflow<br />

installation.)<br />

2. Built-in circulating pump, air purge valve,<br />

and anti-thermosiphon check valve<br />

3. <strong>Co</strong>mpatible with all major brands of split condensing<br />

units and heat pumps<br />

4. <strong>Co</strong>mpatible with all properly sized gas or oilfired<br />

water heaters<br />

5. Slide out hot water coil assembly for easier<br />

service<br />

6. Flue gas safety switch (except 60<strong>MBQ</strong>)<br />

7. Piston-type metering device on cooling coil<br />

8. Factory installed filter<br />

9. Fully insulated and painted galvanized steel<br />

cabinet<br />

10. <strong>Co</strong>pper tube heating and cooling coils<br />

11. Primary and secondary drain connections<br />

on cooling coil<br />

Table of <strong>Co</strong>ntents<br />

Page #<br />

Description ................................................. 1<br />

Features ..................................................... 1<br />

Efficiency .................................................... 2<br />

<strong>Co</strong>mponents ............................................... 2<br />

Installation/Operation .................................. 2<br />

Accessories ................................................ 2,4<br />

Physical Dimensions .................................. 3<br />

Performance Data ...................................... 3<br />

Blower Data ................................................ 3<br />

FIRST CO. - P.O. BOX 270969 - DALLAS, TEXAS 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - www.firstco.com


<strong>MBQ</strong> <strong>Series</strong><br />

DX COOLING<br />

HOT WATER HEATING<br />

Efficiency:<br />

The <strong>MBQ</strong> series air handler is the latest state-of-the-art air handler for hot water heating. Depending on the water<br />

heater efficiency and the condensing unit used, heating efficiency can exceed 90% and cooling efficiency can<br />

exceed 12.0 SEER. <strong>Co</strong>oling coils are also circuited for heat pump operation.<br />

<strong>Co</strong>mponents:<br />

Each air handler includes a high efficiency cooling coil, a separate hot water coil, circulating pump, air purge valve,<br />

anti-thermosyphon check valve, flue gas safety switch (except 60<strong>MBQ</strong>), 120V fan motor, throwaway filter, and 24V<br />

transformer.<br />

Cabinets:<br />

Cabinets are fully insulated and painted with an attractive, baked-on powder coating (light gray).<br />

Installation:<br />

No modification is required for vertical or horizontal (right-to-left) airflow. A horizontal drain pan is factory installed<br />

for right-to-left airflow and can be re-positioned within the cabinet to offer left-to-right airflow. An optional<br />

counterflow conversion kit is available for downflow installations.<br />

Operation:<br />

When space heating is needed, the wall thermostat energizes the circulating pump which circulates hot water from<br />

the water heater to the hot water coil in the air handler. As the fan motor forces cool return air from the home over<br />

the hot water coil, the air absorbs heat from the hot water. This warm air (105 to 110 degrees) is then circulated<br />

throughout the duct system and into the home. The water loses only about 15 degrees of temperature while it<br />

circulates through the coil and is then returned to the water heater to be reheated.<br />

Accessories:<br />

Accessories include counterflow conversion kits, DX expansion valve kits, heat pump expansion valve kits, pump<br />

timer, and freeze protector.<br />

4-WAY AIRFLOW<br />

(60<strong>MBQ</strong> NOT CONVERTIBLE<br />

TO DOWN FLOW)<br />

- 2 -


<strong>MBQ</strong> <strong>Series</strong><br />

DX COOLING<br />

HOT WATER HEATING<br />

Easy<br />

Access<br />

Check<br />

Valve<br />

COIL CONNECTIONS<br />

UNIT<br />

SIZE<br />

LIQUID<br />

SUCTION<br />

18/24<br />

3/<br />

8 5/ 8<br />

30/36<br />

3/<br />

8 3/ 4<br />

48/60<br />

1/<br />

2 7/ 8<br />

PHYSICAL DIMENSIONS<br />

UNIT<br />

MODEL<br />

18<strong>MBQ</strong><br />

24<strong>MBQ</strong><br />

30<strong>MBQ</strong><br />

36<strong>MBQ</strong><br />

A B C D E F G H<br />

FILTER<br />

SIZE<br />

40<br />

20<br />

20<br />

18-1/<br />

2 16<br />

2 18<br />

16<br />

18 X 20 X 1<br />

42<br />

23<br />

20<br />

21-1/<br />

2 16<br />

2 18<br />

19<br />

20 X 22 X 1<br />

48<strong>MBQ</strong><br />

48<br />

28<br />

21-1/<br />

4 26-1/<br />

4 17-1/<br />

4 2 18<br />

24<br />

20 X 25 X 1<br />

60<strong>MBQ</strong><br />

52<br />

28<br />

25-1/<br />

4 26-1/<br />

2 21-1/<br />

4 2 22<br />

24<br />

BLOWER DATA<br />

UNIT<br />

MODEL<br />

MOTOR<br />

HP-AMPS<br />

(120V)<br />

18<strong>MBQ</strong><br />

1/5-2. 8<br />

24<strong>MBQ</strong><br />

1/5-5. 1<br />

30<strong>MBQ</strong><br />

1/5-5. 1<br />

36<strong>MBQ</strong><br />

1/2-8. 5<br />

48<strong>MBQ</strong><br />

3/4-10. 7<br />

60<strong>MBQ</strong><br />

1-11. 5<br />

MOTOR<br />

SPEED<br />

CONN.<br />

HIGH<br />

MED.<br />

MED. LOW<br />

LOW<br />

HIGH<br />

MED.<br />

LOW<br />

HIGH<br />

MED.<br />

LOW<br />

HIGH<br />

MED.<br />

LOW<br />

HIGH<br />

MED.<br />

LOW<br />

HIGH<br />

MED.<br />

LOW<br />

20 X 24 X 1<br />

(2 required)<br />

CFM vs. EXTERNAL STATIC<br />

PRESSURE<br />

0.05<br />

0.10<br />

0.20<br />

0.30<br />

0.40<br />

0.50<br />

810<br />

680<br />

530<br />

350<br />

950<br />

960<br />

780<br />

1120<br />

850<br />

680<br />

1340<br />

1290<br />

1200<br />

1810<br />

1570<br />

1280<br />

2160<br />

1865<br />

1560<br />

780<br />

655<br />

505<br />

325<br />

920<br />

835<br />

755<br />

1095<br />

840<br />

670<br />

1310<br />

1260<br />

1170<br />

1780<br />

1550<br />

1260<br />

2125<br />

1840<br />

1540<br />

715<br />

600<br />

460<br />

270<br />

855<br />

785<br />

705<br />

1045<br />

810<br />

655<br />

1250<br />

1200<br />

1120<br />

1720<br />

1510<br />

1220<br />

2055<br />

1785<br />

1490<br />

650<br />

545<br />

415<br />

220<br />

790<br />

720<br />

650<br />

995<br />

780<br />

625<br />

1190<br />

1140<br />

1070<br />

1660<br />

1460<br />

1180<br />

1980<br />

1710<br />

1435<br />

580<br />

490<br />

360<br />

160<br />

720<br />

650<br />

590<br />

940<br />

740<br />

585<br />

1120<br />

1080<br />

1010<br />

1590<br />

1400<br />

1130<br />

1895<br />

1620<br />

1365<br />

500<br />

420<br />

295<br />

- - -<br />

645<br />

580<br />

510<br />

880<br />

690<br />

510<br />

1050<br />

1000<br />

940<br />

1530<br />

1340<br />

1050<br />

1810<br />

1525<br />

1260<br />

PERFORMANCE DATA<br />

UNIT<br />

MODEL<br />

NOMINAL<br />

COOLING<br />

BTUH<br />

COIL #<br />

(2)<br />

GPM<br />

(HTG.)<br />

P.D.<br />

(FT. WTR.)<br />

BTUH (1000) AT<br />

ENTERING<br />

WATER TEMPERATURE<br />

120°F<br />

130°<br />

F 140°<br />

F 180° F<br />

18<strong>MBQ</strong>-2<br />

18,000<br />

USM318AP<br />

3-1/<br />

2 3.<br />

3 19.<br />

0 22.<br />

8 26.<br />

6 41. 8<br />

18<strong>MBQ</strong>-3<br />

18,000<br />

USM318AP<br />

3-1/<br />

2 4.<br />

3 24.<br />

2 29.<br />

1 33.<br />

9 53. 3<br />

24<strong>MBQ</strong>-2<br />

24,000<br />

USM424AP<br />

3-1/<br />

2 3.<br />

3 19.<br />

7 23.<br />

7 27.<br />

6 43. 4<br />

24<strong>MBQ</strong>-3<br />

24,000<br />

USM424AP<br />

3-1/<br />

2 4.<br />

3 25.<br />

2 30.<br />

3 35.<br />

3 55. 5<br />

30<strong>MBQ</strong>-2<br />

30,000<br />

USM330AP<br />

3-1/<br />

2 4.<br />

0 23.<br />

7 28.<br />

5 33.<br />

2 52. 2<br />

30<strong>MBQ</strong>-3<br />

30,000<br />

USM330AP<br />

3-1/<br />

2 5.<br />

0 31.<br />

1 37.<br />

4 43.<br />

6 68. 5<br />

36<strong>MBQ</strong>-2<br />

36,000<br />

USM436AP<br />

3-1/<br />

2 4.<br />

0 26.<br />

5 31.<br />

8 37.<br />

1 58. 3<br />

36<strong>MBQ</strong>-3<br />

36,000<br />

USM436AP<br />

3-1/<br />

2 5.<br />

0 35.<br />

4 42.<br />

4 49.<br />

5 77. 8<br />

48<strong>MBQ</strong>-3 (1)<br />

48<strong>MBQ</strong>-4 (1)<br />

42,000/<br />

48,000<br />

42,000/<br />

48,000<br />

USM348AP<br />

3-1/<br />

2 2. 1<br />

USM348AP<br />

3-1/<br />

2 3. 4<br />

39.9<br />

42.4<br />

45.9<br />

49.1<br />

47.8<br />

50.8<br />

55.0<br />

59.0<br />

(1) Use 48<strong>MBQ</strong> for 3.5 ton applications and field-convert fan motor to low speed.<br />

(2) See "USM" data sheet for additional coil information.<br />

55.8<br />

59.3<br />

64.2<br />

68.8<br />

87.7<br />

93.2<br />

100.8<br />

108.1<br />

60<strong>MBQ</strong>-3<br />

60,000<br />

USM460AP<br />

7 7.<br />

6 57.<br />

7 69.<br />

3 80.<br />

8 127. 0<br />

60<strong>MBQ</strong>-4<br />

60,000<br />

USM460BP<br />

7 8.<br />

8 65.<br />

0 78.<br />

0 91.<br />

0 143. 0<br />

NOTES:<br />

1. Heating output of fan coil will not exceed net output of water heater.<br />

2. Approved for installation with 0" clearance to combustible materials.<br />

3. Heat BTUH is at 70 degree entering air temperature.<br />

ELECTRICAL DATA<br />

UNIT<br />

MODEL<br />

MOTOR<br />

HP<br />

(120V)<br />

A MPS MIN. CIR .<br />

PUMP<br />

AMPACITY<br />

MOTOR<br />

MAX<br />

HACR<br />

BREAKER<br />

18<strong>MBQ</strong><br />

1/<br />

5 2.<br />

8 0.57<br />

5 15<br />

24<strong>MBQ</strong><br />

1/<br />

5 5.<br />

1 0.57<br />

7 15<br />

30<strong>MBQ</strong><br />

1/<br />

5 5.<br />

1 0.57<br />

7 15<br />

36<strong>MBQ</strong><br />

1/<br />

2 8.<br />

5 0.57<br />

12<br />

15<br />

48<strong>MBQ</strong><br />

3/<br />

4 10.<br />

7 0.57<br />

14<br />

15<br />

60<strong>MBQ</strong><br />

1 11.<br />

5 0.75<br />

16<br />

20<br />

- 3 -


ACCESSORIES - (all field installed)<br />

EXPANSION VALVE KITS<br />

TYPE<br />

DX<br />

(Straight <strong>Co</strong>ol)<br />

HEAT PUMP<br />

FITS<br />

18, 24<strong>MBQ</strong><br />

30, 36<strong>MBQ</strong><br />

48<strong>MBQ</strong><br />

60<strong>MBQ</strong><br />

18, 24<strong>MBQ</strong><br />

30, 36<strong>MBQ</strong><br />

48, 60<strong>MBQ</strong><br />

KIT NUMBER<br />

978-5<br />

978-6<br />

978-7<br />

978-8<br />

978-5HP<br />

978-6HP<br />

978-7HP<br />

Notes:<br />

1. Valves mount inside air handler cabinet.<br />

2. Valves are externally equalizing, internal bleed type.<br />

3. Heat Pump valves check internally.<br />

COUNTERFLOW CONVERSION KITS<br />

FITS<br />

KIT NUMBER<br />

18, 24<strong>MBQ</strong><br />

919-11<br />

30, 36<strong>MBQ</strong><br />

919-12<br />

48<strong>MBQ</strong><br />

919-13<br />

Notes:<br />

1. <strong>Co</strong>unterflow conversion not recommended where<br />

the air handler is installed above a finished ceiling.<br />

2. No kit available for 60<strong>MBQ</strong>. This model is not approved<br />

for counterflow installation.<br />

MISCELLANEOUS<br />

COMPONENT<br />

Freeze Protector<br />

Pump Timer<br />

Thermostat<br />

DESCRIPTION<br />

Energizes pump when<br />

coil temperature falls<br />

below 38°F<br />

Energizes pump for 30<br />

seconds every 6 hours<br />

PART NUMBER<br />

941-1<br />

E1242<br />

24V Heat/<strong>Co</strong>ol<br />

T334<br />

Notes:<br />

1. Freeze protector attaches to hot water coil and<br />

wires to low voltage (24V) circuit.<br />

2. Pump timer is low voltage (24V).<br />

"In keeping with its policy of continuous progress and<br />

product improvement, <strong>First</strong> <strong>Co</strong>. reserves the right to make<br />

changes without notice."<br />

Catalog No. <strong>MBQ</strong>1000 (Replaces <strong>MBQ</strong>100)<br />