Review

Role of Endoscopic Ultrasound in Diagnosis of Pancreatic Ductal Adenocarcinoma

by
Abhirup Chatterjee
and
Jimil Shah
*
Department of Gastroenterology, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh 160012, India
*
Author to whom correspondence should be addressed.
Diagnostics 2024, 14(1), 78; https://doi.org/10.3390/diagnostics14010078
Submission received: 4 December 2023 / Revised: 26 December 2023 / Accepted: 27 December 2023 / Published: 28 December 2023
(This article belongs to the Special Issue Diagnostic Value of Endoscopic Ultrasound for Pancreatic Diseases)

Abstract

:
Pancreatic ductal adenocarcinoma (PDAC) is the most common (90%) type of solid pancreatic neoplasm. Due to its late presentation and poor survival rate, early diagnosis and timely treatment is of utmost importance for better clinical outcomes. Endoscopic ultrasound provides high-resolution images of the pancreas and has excellent sensitivity in the diagnosis of even small (<2 cm) pancreatic lesions. Apart from imaging, it also has an advantage of tissue acquisition (EUS fine-needle aspiration, FNA; or fine-needle biopsy, FNB) for definitive diagnoses. EUS-guided tissue acquisition plays a crucial role in genomic and molecular studies, which in today’s era of personalized medicine, are likely to become important components of PDAC management. With the use of better needle designs and technical advancements, EUS has now become an indispensable tool in the management of PDAC. Lastly, artificial intelligence for the detection of pancreatic lesions and newer automated needles for tissue acquisition will obviate observer dependency in the near future, resulting in the wider dissemination and adoption of this technology for improved outcomes in patients with PDAC.

1. Introduction

Pancreatic ductal adenocarcinoma (PDAC) is the most common type of solid pancreatic neoplasm comprising more than 90% of all solid pancreatic neoplasms [1]. Although conventionally considered a disease of the elderly with the median age of detection being 71 years, recent data from the Surveillance Epidemiology and End Results Program (SEER) and the Center for Disease Control (CDC) have revealed an increasing rate of pancreatic cancer with a greater number of cases being detected among young individuals [2,3]. In a large population-based study from the Cedars-Sinai Medical Center group, the age-adjusted incidence rate (aIR) was found to be alarmingly increasing between 2001 and 2018 among young patients < 55 years old (more so in the group that was 15–34 years old) [2]. Further population-based cancer registry data show an increase in its annual incidence of 0.77%, 2.47%, and 4.34% in the age groups of 45–49 years, 30–34 years, and 25–29 years, respectively, and it is projected to be the second most fatal cancer by 2030 [2,3,4,5,6]. Despite its increasing incidence, pancreatic cancer remains one of the most fatal malignancies with a grave 5-year survival rate of only 10–12% [2]. The major hindrance in improving patient prognosis is the lack of clearly defined risk factors, lack of targeted surveillance protocols or populations, and absence of specific symptoms or specific biomarkers. Due to these factors, the clinical presentation of patients is delayed, and only 10–15% of patients are in an operable stage at the time of presentation [3,7]. So, early diagnosis and treatment are of utmost importance in improving the prognosis of PDAC. Since its introduction, endoscopic ultrasound (EUS) has been used for the detection of pancreatic mass lesions and their characterization. Initially, only B-mode imaging was available in EUS for the characterization of lesions. However, with advancements in technology, various imaging modes like EUS elastography and contrast-enhanced EUS (CE EUS) are now available for better lesion characterization. Similarly, since its introduction, EUS-guided fine-needle aspiration (FNA) has become a cornerstone in tissue diagnoses of pancreatic mass lesions. Various dedicated aspiration and biopsy needles have been developed over the last two decades, providing a high diagnostic accuracy and high-quality histological core to perform molecular studies. Apart from its diagnostic role, EUS has a therapeutic implication in the management of various aliments associated with pancreatic carcinoma, like celiac plexus neurolysis or RFA (radiofrequency ablation) for pain management, EUS-guided biliary drainage (as a primary modality or rescue therapy), EUS-guided gastrojejunostomy for the management of gastric outlet obstructions, and EUS-guided RFA for locally advanced tumors [8,9]. In this dedicated review, we focus our discussion on the recent advances and the current role of EUS in the diagnosis of PDAC.

2. EUS in the Detection of Tumors

EUS is now a well-established modality in the detection of pancreatic lesions. Due to its proximity with the entire pancreatic parenchyma from the stomach to duodenum and good spatial resolution, even small lesions can be detected with a high accuracy. Compared to abdominal ultrasound, in which the entire pancreas might not be evaluated due to gas artifacts or body habitus, EUS has a better accuracy in detecting pancreatic lesions by obviating both these problems. Studies have shown that the sensitivity of EUS is higher than that of transabdominal ultrasound and computed tomography (CT) scans (94% vs. 67% vs. 74%; p < 0.05) in the diagnosis of PDAC [10]. EUS is even more clinically useful in the presence of small lesions (<2 cm), as it provides a higher detection accuracy compared to that of CT or magnetic resonance imaging (MRI). In a study by Muller et al., EUS had a better sensitivity compared to that of CT and MRI for the detection of small pancreatic lesions < 30 mm (93% vs. 53% and 67%, respectively) [11]. Similarly, in another study by Sakamoto et al., EUS proved to be superior to CT for lesions smaller than 20 mm with a sensitivity of 94.4% (vs. 50%) [12]. Additionally, for lesions smaller than 10 mm, EUS has shown a higher sensitivity compared to that of transabdominal ultrasound, CT, and PET scans (sensitivity > 80%, 17–70%, 33–75%, and 50%, respectively) [13]. In a meta-analysis involving 206 patients with suspected pancreatic masses but indeterminate CT scans, EUS showed a pulled sensitivity, specificity, and accuracy of 85%, 58%, and 75%, respectively, in the detection of pancreatic lesions. Pancreatic masses were diagnosed in 70% of patients (42% were adenocarcinoma) with a mean tumor size of 21 ± 1.2 mm, which highlights the impact of EUS for small lesions of the pancreas [14]. Similarly, EUS is more accurate compared to MRI in the detection of solid pancreatic lesions (100% vs. 22%; p < 0.001) in high-risk individuals during the surveillance period [15].
For B-mode EUS imaging, PDAC usually appears as a heterogenous, hypoechoic mass lesion with irregular borders. There might be upstream parenchymal atrophy with or without main pancreatic duct dilation [16]. Pancreatic in situ carcinoma might present as just focal narrowing/stricture in the pancreatic duct with surrounding hypoechoic areas [17]. However, some lesions can also have atypical features, such as the presence of a small amount of calcification, cystic areas, or isoechoic lesions, compared to surrounding pancreatic parenchyma. Compared to this finding, pancreatic neuroendocrine tumors usually present as well-circumscribed, homogenous, hypoechoic lesions with clearly regular borders. In comparison, autoimmune pancreatitis might have a homogenous lesion that is hypoechoic in nature with parenchymal heterogenicity and bile duct wall thickening [16]. However, these findings are not entirely specific to PDAC; other lesions like mass-forming chronic pancreatitis, lymphoma, pancreatic tuberculosis, or metastatic tumors in the pancreas can also produce similar findings. So, histological prediction is difficult in some patients when it is only based on B-mode imaging, necessitating the need for tissue acquisition from the same setting.

3. Role of EUS in the Staging of Tumors

EUS is helpful in the locoregional staging of pancreatic adenocarcinoma in terms of vascular involvement, lymph node metastases, the detection of small hepatic metastasie, and the diagnosis of minimal ascites or peritoneal carcinomatosis. Studies have shown that EUS is more accurate in the detection of vascular involvement compared to CT scans, especially in the detection of venous involvement. The sensitivity and specificity of EUS for the detection of tumor vascular invasion range from 42% to 91% and from 89% to 100%, respectively, in different studies [10]. In a meta-analysis involving 30 studies with 1554 patients, the pooled sensitivities of EUS and CT were 72% and 63%, respectively, and the pooled specificities of EUS and CT were 89% and 92%, respectively. In a sub-group analysis of nine studies in which EUS and CT were both performed, CT showed a lower sensitivity compared to that of EUS (48% vs. 69%) [18]. Moreover, the sensitivity of EUS is also higher for the detection of portal vein involvement compared to superior mesenteric vein/artery or celiac artery involvement. This may be due to technical difficulties in providing entire images of these vessels, due to obscuration by large tumors in the uncinate or inferior portion of the pancreatic head [10]. Contrast-enhanced EUS (CE EUS) can be also of value in detecting subtle portal venous involvement missed by conventional EUS or CT [19,20]. There are four types of vascular involvement in pancreatic cancer: type 1, clear invasion with the encasement of a vessel by a tumor; type 2, a tumor that is in contact with a vessel with the loss of the hyperechoic vessel layer with or without vessel irregularity or luminal narrowing; type 3, a tumor that contacts a vessel without the loss of the hyperechoic vessel layer; and type 4, clear non-invasion with distance between the tumor and vessel [21]. Apart from that, tumor thrombus within the vessel or the presence of collaterals surrounding the tumor can also be found [22] (Figure 1).
For N staging, a meta-analysis has also shown that EUS has a better sensitivity (58% vs. 24%) and a similar specificity (85% vs. 88%) to those of CT in detecting lymph node involvement [23,24]. Malignant lymph nodes on EUS usually have a size > 10 mm, a round shape, a sharply demarcated border, and are hypoechoic in nature [25].
EUS also has a beneficial role in the diagnosis of small hepatic malignancies. In a prospective study by Okasha HH et al., EUS could detect 7.9% of incremental focal liver lesions and 5.8% of liver metastases that were missed by CT and MRI imaging, with the median size of the hepatic lesions being 12 mm [26]. From another prospective study by Singh P et al., EUS also showed a better sensitivity compared to that of CT in the diagnosis of small liver lesions (40% vs. 19%; p = 0.008) [27]. EUS has a better accuracy in detecting minimal ascites or omental thickening in pancreatic carcinoma, and sampling can be performed withing the same session for the detection of metastases to avoid futile surgeries [28,29]. Similarly, a diagnosis of perivascular cuffing suggestive of extravascular migratory metastases (EVMMs) can be made via EUS. In a study by Rustogi T et al., EUS could detect EVMMs that were initially missed by CT or MRI as perivascular cuffing in an additional 28% of patients with PDAC. In that study, the disease was upstaged in 14 patients from resectable to unresectable after EUS-guided FNA of EVMMs [30]. Similarly, in a recent meta-analysis involving 795 patients, EUS could identify unresectable disease in 14% of patients in whom initial cross-sectional imaging showed resectable disease [31] (Figure 2). So, EUS is an extremely valuable modality in patients with potentially resectable disease for accurate T and N staging as well as the diagnosis of previously missed hepatic metastases, ascites, or EVMMs, so that futile laparotomies can be avoided. However, being operator-dependent, interobserver variability and the availability of a trained physician are of utmost importance in providing optimal clinical results. The National Comprehensive Cancer Network (NCCN) and European Society of Medical Oncology (ESMO) guidelines also recommend EUS for equivocal pancreatic lesions that are iso-dense in CT and the assessment of venous involvement. A biopsy may be obviated in resectable cases of patients who are scheduled for direct surgery; however, tissue diagnosis is required for borderline or locally advanced lesions before starting chemotherapy [32,33].

4. Role of Contrast-Enhanced EUS

CE EUS allows for the characterization, differential diagnosis, and accurate staging of pancreatic lesions. Typically, pancreatic carcinoma is hypo-enhancing, neuroendocrine tumors are hyper-enhancing, and autoimmune pancreatitis/mass-forming pancreatitis is iso-enhancing compared to surrounding pancreatic parenchyma on CE EUS [34] (Figure 3). A recent meta-analysis has shown a pooled sensitivity and specificity of 91% and 86%, respectively, in the diagnosis of pancreatic adenocarcinoma [35]. Apart from the qualitative image, a quantitative analysis using a TIC (time-intensity curve) can be also of value in evaluating CE EUS images. A TIC shows peak enhancement values, which help in the differentiation of chronic pancreatitis from pancreatic carcinoma [36]. Moreover, the peak enhancement value also shows a correlation with microvascular density in histological analyses [37]. CE EUS has also been shown to perform better compared to conventional EUS in characterizing vascular invasion by mass lesions. After contrast injection, portal vein borders can be delineated better, resulting in a higher accuracy compared to that of conventional EUS or CT scans. In a single-center, retrospective study by Nakai A et al., the diagnostic accuracy of CE EUS was better than that of B-mode EUS or CT for diagnosing portal vein invasion (93.2%, 72.7%, and 81.8%, respectively; p < 0.05) [19]. In a similar study by Imazu H et al., the accuracy of the T staging of CE EUS was better compared to that of conventional EUS (92.4% vs. 69.2%; p < 0.05) [38]. Similarly, prospective studies have also shown that the use of contrast-enhanced EUS (CE EUS) has a better sensitivity compared to that of CT or EUS in detecting small liver lesions < 10 mm in size (93.3% vs. 84.4% vs. 85.6%, respectively; p < 0.05) [39,40]. On CE EUS, lymph nodes can also be examined for enhancement patterns, with malignant lymph nodes showing a heterogeneous enhancement pattern compared to benign lymph nodes. In a study by Miyata T et al., the heterogenous enhancement pattern on CE EUS had better sensitivity compared to conventional EUS for the assessment of lymph nodal metastases [41]. Apart from its diagnostic role, CE EUS also helps in the selection of the target area for EUS-guided FNA. In a recent meta-analysis involving six studies and 701 patients, the pooled sensitivity of CE EUS-guided FNA was higher than that of EUS-guided FNA (84.6% vs. 75.3%; p < 0.001) [42]. However, in a recent randomized trial comparing CE EUS-guided FNB and conventional FNB with fanning techniques, both arms had a similar diagnostic accuracy with similar requirements for the median number of passes [43]. So, with the advent of newer EUS FNB (fine-needle biopsy) needles, the routine use of CE EUS before EUS tissue acquisition (EUS TA) remains questionable.

5. EUS Elastography

Like CE EUS, EUS elastography has also been used for the better characterization of pancreatic mass lesions. Two types of EUS elastography are strain elastography and shear wave elastography. In strain elastography, interpretations can be both qualitative (using a color pattern) or quantitative (using the strain ratio (SR) or strain histogram (SH)). On qualitative examination, pancreatic malignant tumors are heterogeneous, predominantly having a blue pattern (hard signal) with small green areas and a geographic appearance compared to pancreatic neuroendocrine malignant lesions, which have a homogenous blue pattern [44] (Figure 4). In a quantitative analysis, a SR greater than 10 represents hard tissue (likely to be malignant) and <10 is intermediate (likely to be benign) [45]. A SH mean < 50 indicates hard tissue suggestive of a malignancy, whereas a SH of 50–150 (intermediate) and >150 (intermediate-soft) indicate it is more likely to be benign [45]. In a study among 86 consecutive patients with solid pancreatic lesions, the mean SR for adenocarcinoma was 18.12 (95% CI 16.03–20.21) and for inflammatory masses was 3.28 (95% CI 2.61–3.96), and both were significantly higher compared to those of a normal pancreas (mean SR of 1.68) [45]. In a subsequent study, authors showed that for malignant pancreatic tumors, at a cut-off of a SR >10 and a SH < 50, the sensitivity and specificity were 100% and 92.3%, respectively [46]. In another study, the use of EUS elastography was superior to dynamic CT and B-mode EUS with a higher sensitivity, specificity, and accuracy for staging pancreatic carcinoma with a better delineation of vascular involvement [47]. Facciorusso A et al. evaluated the utility of EUS-elastography-guided FNA for pancreatic lesions, and its diagnostic accuracy, sensitivity, and specificity were favorable (94.4%, 93.4%, and 100%, respectively) [48]. As it is a simple inbuilt procedure within the existing EUS system, no extra cost is involved for the patient. In recent times, shear wave elastography (SWE) has also been introduced into the EUS system; however, in the absence of prospective data and standardization, its role in pancreatic carcinoma is yet to be explored [49].

6. EUS-Guided Tissue Acquisition: Techniques and Variations

In recent years, the role of neoadjuvant chemotherapy has significantly expanded to improve clinical outcomes in patients with borderline resectable and locally advanced PDAC. Moreover, recently, neoadjuvant chemotherapy has also been explored in resectable PDAC to improve clinical outcomes. Subsequently, the role of pre-operative tissue diagnosis for neo-adjuvant chemotherapy and precision medicine has also expanded in recent times [32,50]. EUS tissue acquisition is a procedure in which tissue is procured from the target lesion under endosonographic guidance using dedicated needles to establish a tissue diagnosis. Apart from tissue acquisition from the primary tumor, EUS also offers a sampling of locoregional and distant lymph nodes, concomitant liver lesions (suspicious metastases), and minimal ascites, which have a seminal role in management decisions. Studies have shown that EUS TA has a better accuracy compared to that of EUS- or CT-guided tissue acquisition in patients with pancreatic lesions [51]. Moreover, in the last decade, EUS TA has undergone a paradigm shift due to the availability of different needles, different modes of suction, and sample handling techniques to yield a better tissue material equivalent to the histological core [52].

6.1. EUS FNB and FNB Needles

6.1.1. EUS FNB Needles

Currently, a plethora of EUS FNB needles are available from various manufacturers (for example, EZ Shot 3 Plus, Olympus; Echotip Ultra, Cook; Expect and Expect Slimline, Boston Scientific) in different diameters, starting from the stiffer 19G needles to the more flexible 20G, 22G, and 25G needles. Stiff 19G needles, despite their presumed superior diagnostic accuracy, are difficult to maneuver, especially for head lesions, and can lead to scope trauma and technical failures [53]. To obviate this problem, 19G Nitinol needles were designed with better flexibility. Laquiere A et al. conducted a randomized trial comparing the 19G nitinol needle with the 22G needle for a trans-duodenal puncture from pancreatic solid lesions. The 19G needle had a lower technical success rate (86.4% vs. 100%; p = 0.003), lower diagnostic accuracy (69.5% vs. 87.3%; p = 0.02), and inferior ergonomic score (p < 0.001) compared to the 22G needle [54]. The 25G needle is more flexible, easily maneuverable, has a lower risk of blood contamination and improved accessibility for smaller and hypervascular lesions, and is preferred for sampling from difficult-to-access sites like uncinate process lesions and from more fibrous solid lesions. Madhoun MF et al. conducted a meta-analysis of eight studies involving 1292 subjects and the 25G needle had a higher sensitivity compared to that of the 22G (93% vs. 85% respectively) with a similar specificity (97% vs. 100%) [55]. However, two other meta-analyses have failed to show any significant difference between the 22G and 25G EUS FNB needles [56,57]. Recent ESGE Guidelines on EUS-guided tissue acquisition also recommend 22G or 25G needles for EUS TA from pancreatic solid lesions [58].

6.1.2. EUS FNB Needles

Though EUS FNA needles can provide tissue for cytological yield, their diagnostic accuracy is limited in the presence of pauci-cellular tumors or marked desmoplastic reactions as well as in situations in which the examination of tissue stroma is essential, like in lymphoma. EUS FNB has the advantage over FNA due to its ability to acquire a higher cell count, maintain tissue architecture, and provide tissue for molecular profiling [59]. EUS FNB needles have evolved significantly over the years in terms of their design and technical modifications. EUS FNB needles can be divided into first-generation true-cut needles (Quick core, 19G, Cook Endoscopy, Limerick, Ireland), second-generation reverse-bevel needles (Echo Tip Procore needle (19, 22, and 25G) Cook Endoscopy, Limerick, Ireland), and third-generation needles (fork-tip needle, e.g., shark core needle by Medtronic, Minneapolis, MN, USA; Franseen tip needle, e.g., Acquire needle by Boston Scientific, Marlborough, MA, United States; SonoTip TopGain needle by Medi-Globe, Achenmühle, Germany; and the forward-facing bevel needle with core-trap technology, e.g., Procore needle by Cook Medical, Limerick, Ireland) (Table 1). Though earlier studies on first-generation needles showed equivalent diagnostic yields between EUS FNB and EUS FNB (although fewer passes were required in the former group), subsequent high-quality prospective studies and randomized controlled trials using second- and third-generation EUS FNB needles show the superiority of EUS FNB over FNA [60]. In a multi-center RCT by Cheng et al., a subgroup analysis for patients with pancreatic masses showed the superior diagnostic accuracy of the reverse-bevel EUS FNB needle over the 25G EUS FNB needle (93% vs. 82%, respectively, p < 0.01) [61]. In a similar study by van Riet et al., the forward-bevel Procore 20G EUS FNB needle a showed superior diagnostic accuracy (87% vs. 78%, p = 0.002) and histological tissue yield (77% vs. 44%, p < 0.001) compared to those when using EUS FNB needles [62]. In a recent meta-analysis by Renelus BD et al. involving 19 studies (1365 patients), FNB had a better diagnostic accuracy (87% vs. 81%; p = 0.005), better cytopathological accuracy (87% vs. 81%; p = 0.005), and reduced number of passes required (1.6 vs. 2.3; p < 0.001) with similar adverse event rates (1.8% vs. 2.3%; p = 0.64) compared to FNA [63].
Regarding the various types of FNB needles, an RCT compared the 22G Franseen needle (Acquire) with the 20G forward-bevel Procore needle, in which the Franseen needle showed a significantly higher tissue length (mean length of 11.4 mm vs. 5.4 mm, p < 0.001) and surface area (mean surface area of 3.5 mm2 vs. 1.8 mm2, p < 0.001) of the sample compared to those of the 20G Procore needle. Higher diagnostic adequacy was obtained with the Franseen needle (87% vs. 67%, p = 0.02) [64]. In other studies, in suspected type 1 autoimmune pancreatitis patients, similar results were shown [65]. In randomized trials, Franseen needles and fork-tip needles were similar in terms of diagnostic adequacy (94.9–96% vs. 92–97.2%), and accuracy (92.3% vs. 94.4%) [66,67]. In a systematic review and meta-analysis among patients with solid mass lesions, both fork-tip and Franseen needles had similar diagnostic yields (92.8% vs. 92.7%, p = 0.98), with and without using ROSE (95.9 vs. 93.7%; p = 0.25) and between ≤two and >two needle passes (90.6% vs. 93.3%; p = 0.56) [68]. In a recent network meta-analysis of 16 RCTs (n = 1934) comparing different types of FNB needles in sampling pancreatic solid masses, Franseen and fork-tip needles were the two best-performing EUS FNB needles with significant advantages over reverse-bevel needles and EUS FNB needles for diagnostic accuracy and tissue adequacy. However, no significant difference was found between Franseen and fork-tip needles. Regarding diagnostic accuracy, both 22G Franseen and fork-tip needles were superior to 22G reverse-bevel needles (RR, 1.22 (95% CI, 1.03–1.44) and 1.19 (95% CI, 1.03–1.38), respectively). For sample adequacy, the 25G Franseen needle was superior to the 22G reverse-bevel needle (RR, 1.12 (95%CI, 1.02–1.22)). The 22G Franseen needle was found to be the best-performing EUS FNB needle regarding diagnostic accuracy, and the 22G and 25G Franseen needles followed by the 22G fork-tip needle were the two best-performing needles regarding sample adequacy [69]. Moreover, apart from diagnostic accuracy, these needles have also shown better performance in terms of the genetic profiling of tumors, the detection of actionable molecular alterations, and microsatellite instability (MSI), which have significant implications in personalized treatment as discussed below.

6.2. Technical Aspects in EUS TA

To maintain tissue integrity, improve the cellularity of the sample, and reduce blood contamination, various suction and sampling techniques have been described in the literature, including dry suction, wet suction, capillary suction with the stylet slow-pull technique (CSSS), door knock, and fanning techniques. In the conventional suction method, 10 mL of negative pressure is usually used, though a higher negative pressure has shown superior tissue adequacy in studies [70,71,72]. The wet suction technique was found to be superior in terms of tissue adequacy and cellularity in prospective randomized studies [73,74,75]. In a systematic review and meta-analysis of six studies (n = 418) including three RCTs, the wet suction technique was shown to be superior to the dry suction technique in terms of sample adequacy (pooled OR of 3.18; 95% confidence interval (CI): 1.82–5.54; p = 0.001) with no significant difference in blood contamination and histological diagnosis [76]. The stylet slow-pull technique has shown comparable results to conventional suction techniques with a mean of two passes for solid pancreatic lesions [77,78,79]. For cirrhotic patients and in the presence of coagulopathy, suction is usually avoided as it increases contamination in blood [80]. Keeping the stylet provides a few additional advantages by increasing the stiffness of the needle and helping remove material obtained from gastrointestinal wall punctures [80]. In a recent network meta-analysis of 16 studies (n = 2048), these techniques were compared (including no suctioning and the wet suction, dry suction, and stylet slow-pull techniques), and no difference among the various suction techniques was found in terms of their tissue adequacy, diagnostic accuracy, and moderate-to-high levels of cellularity. When adjusted for the effect of the type of needle used, no difference was found among these techniques in terms of the bloodiness of the sample [81]. So, the decision to use suctioning and the type of suctioning should be made using more of an individualized approach, depending on the type of lesion, presence of comorbidities, and operator experience.
Regarding the different techniques of EUS TA, the fanning technique and door-knock technique are the most used techniques during the needle pass. In the fanning technique, the elevator and big wheel of the scope are used to change the trajectory of the needle to improve diagnostic accuracy by sampling from different areas of the lesion. In a randomized trial by Bang JY et al., the fanning technique was found to require a fewer number of passes for diagnosis (median of 1 (interquartile range 1–3) vs. 1 (1–1); p = 0.02) and had higher accuracy of diagnosis after the first pass (57.7% vs. 85.7%; p = 0.02) compared to the standard technique [82]. In a prospective study, the slow-pull plus fanning technique has been shown to have a superior diagnostic accuracy (88% vs. 71%, p = 0.044) and less blood contamination (77% vs. 56%, p = 0.041) compared to the standard suction technique [83]. In the door-knock technique, the needle hits the handle after a sharp smart movement into the target, which produces a knocking sound. In a multicenter prospective cross-over trial, the tissue acquisition rate of the door-knock technique was found to be similar to that of the conventional method; however, the tissue acquired from the door-knock technique had high levels of cellularity compared to those acquired from the conventional method (54.9% vs. 41.5%, p = 0.03) [84].
Regarding the required optimum number of passes and actuation during EUS TA, Uehara et al. conducted a retrospective study in which they showed the optimum number of passes required for lesions in the head of the pancreas with a size less than 15 mm was three. For a lesion in the head region that is >15 mm in size or a lesion in the body/tail that is < 15 mm in size, the optimum number of passes was two, and for a lesion in the body or tail region >15 mm in size, only one pass was adequate. The overall sensitivity was 93% using this approach [85]. Recently Paik WH et al., did a randomized trial comparing various suction methods and actuation per pass for pancreatic solid mass. In that study, 15 actuation per pass had better diagnostic accuracy compared to 10 actuations with non-suction techniques. However, when using suction or CSSS, diagnostic accuracy between 10 and 15 actuation was similar [86]. However, both these studies were performed using FNA needles. Zhou W et al. conducted a randomized trial using the 22G FNB needle for the sampling of pancreatic solid lesions. The authors recommended at least three passes using suctioning or four passes without suctioning for the optimal diagnostic accuracy in patients with solid pancreatic lesions [87]. Takahashi K et al. performed a multicentric randomized trial comparing three vs. twelve to-and-fro (TAF) movements in patients with solid pancreatic tumors using the FNB needle. In that study, the diagnostic accuracy of three TAFs was not inferior to that of twelve TAFs (88.6% vs 89.5%) with less blood contamination with three TAFs compared to twelve TAFs [88].

6.3. Role of On-Site Evaluation of the Sample (ROSE and MOSE)

6.3.1. ROSE in EUS TA

The presence of on-site cytopathologists increases the likelihood of adequate tissue sampling and helps in real-time diagnoses to deter endosonologists from taking unnecessary extra samples. However, they have limited availability, especially in resource-constrained settings with an added cost that might not be justifiable in routine clinical practice. In an initial study by Wani et al., the addition of ROSE (rapid on-site evaluation) was associated with fewer passes (the median number of passes was four vs. seven, p < 0.0001) with a similar diagnostic accuracy, procedure time, number of adverse events, and cost when compared to those of EUS FNB without a cytopathologist [89]. Subsequently, in a randomized non-inferiority trial, seven passes without an on-site pathologist were shown to be non-inferior to EUS FNB with an on-site pathologist (the absolute difference was 0.2%) [90]. Recently, Crino SF et al. conducted a multi-center randomized trial comparing EUS FNB with or without ROSE in patients with solid pancreatic lesions. Both arms showed a similar diagnostic accuracy (96.4% vs. 97.4%; p = 0.396). EUS FNB without ROSE had a higher tissue core rate (70.7% vs. 78.0%; p = 0.021) and a reduced procedure time compared to EUS FNB with ROSE [91]. Similarly, Chen YI conducted a multicentric trial comparing EUS FNB with EUS FNB+ROSE in patients with pancreatic lesions. Both arms had a similar diagnostic accuracy (92.2% vs. 93.3%; p = 0.72) with a lower number of passes required in the EUS FNB group (2.3 vs. 3.0; p < 0.001) compared to the EUS FNB + ROSE group [92]. These studies show that the routine use of ROSE in the presence of newer generations of FNB needles is limited.

6.3.2. MOSE in EUS TA

Macroscopic on-site evaluation (MOSE) was first introduced by Iwashita et al., who described the macroscopic visible core (MVC) as whitish or yellowish bulky tissue fragments in the absence of liquid and paste-like material. In that study, the investigators used the 19G EUS FNB needle and found that an MVC > 4mm indicates sample adequacy and can improve diagnostic adequacy. In their multivariate analysis, pancreatic lesions (OR 2.92, 95% CI: 1.06–9.09, p = 0.03) and an MVC ≤ 4mm (OR 15.12, 95% CI: 5.81–45.02, p < 0.0001) had higher false negative results [93] (Figure 5). In a prospective study among 204 patients using the 22G Franseen tip EUS FNB needle for sampling solid pancreatic lesions, the authors found a high accuracy at an MVC cut-off length of ≥3 mm, especially when scheduled for next-generation sequencing (NGS) [94]. In a multicentric randomized trial, involving lesions more than 2 cm in size, EUS TA with MOSE had a similar diagnostic accuracy (92.6% vs. 89.3%, p = 0.37) to that of conventional EUS TA with fewer passes required (two vs. three; p < 0.001) [95] (Table 2).

6.4. Role of Repeat EUS TA

Although EUS TA (especially EUS FNB) has shown excellent sensitivity and diagnostic accuracy, studies have shown that 5–10% of cases might have inconclusive results for which the role of repeat EUS TA has been explored. In retrospective studies, repeat EUS FNB in solid pancreatic lesions has been shown to reveal diagnoses in three-fourths of cases with second EUS FNB showing a sensitivity of 80% [119]. In another study, the location of the lesion, number of needle passes, type of needle used, diameter of the needle, and use of suction were found to influence the performance of a repeat EUS TA. In this study, body or tail lesions (vs. head, p = 0.005), ≥four passes (vs. ≤three passes, p = 0.011), the FNB needle (vs. FNA needle; p = 0.004), the 22G needle (vs. 19/20G needle; p = 0.014), and the use of suctioning (vs. other methods; p = 0.020) have been shown to improve the diagnostic yield in solid pancreatic lesions in a multivariate analysis [120].

6.5. Effect of Biliary Drainage on EUS TA

There is no clear consensus to date regarding the appropriate chronology of EUS TA and ERCP for extrahepatic biliary obstructions [121,122]. EUS TA has its limitations when there is a biliary stent in situ (plastic or metal). This is due to stent-related artefacts, stent-induced local inflammation, acoustic reverberations, and shadowing [123,124]. Studies have reported there is a risk of understaging periampullary lesions resulting in unjustified laparotomies due to the presence of biliary stents [125]. In a recent meta-analysis of nine studies, EUS TA was shown to have lower diagnostic accuracy (for reportedly confirmed malignancies; OR of 0.58; 95% CI, 0.46–0.74; I2 = 0.0%) and comparable tissue inadequacy (OR of 1.12; 95% CI, 0.76–1.65; I2 = 0.0%) in groups in the presence of a stent compared the absence of a stent [115].

6.6. Complications of EUS TA and Risk of Needle Tract Seeding (NTS)

EUS TA is minimally invasive and the risk of complications is minimal, which includes abdominal pain, pancreatitis, bleeding, perforation, infection, and needle track seeding (NTS) with an overall frequency ranging from 0 to 3% [80,126]. The majority of complications are mild and can be managed conservatively. NTS is an anticipated risk of EUS TA especially for body and tail lesions of the pancreas when sampled through the trans-gastric route. Park J S et al. conducted a retrospective study of 528 patients with distal pancreatic cancer who underwent distal pancreatectomies. Among these, 193 patients had undergone EUS FNB before surgery, and 335 had not. After resectioning, the recurrence rates were comparable amongst both groups (EUS FNB: 72.7%; non-EUS FNB: 75%; p = 0.58) at a median follow-up of 21.7 months and there was an equal cancer-free survival rate across both the groups (p = 0.58) [127]. In a retrospective study by Yane et al., the 5-year cumulative risk of NTS was shown to be 3.8% (95% CI 1.6–7.8%) without significantly affecting overall survival and median recurrence-free survival rates [128]. In a recent meta-analysis involving 10 studies (13,238 patients), the pooled rate of NTS was 0.3%. There was no difference in terms of metachronous peritoneal dissemination observed between patients who underwent EUS TA and non-sampled patients [42]. So, NTS after EUS TA remains an important parameter to consider before performing EUS TA; however, it is not associated with reduced cancer-free or overall survival.
In the authors’ personal experience, EUS TA starts initially with an optimum B-mode image examination, the localization of masses and their vascular involvement, and the confirmation of the presence or absence of local lymphadenopathy. For EUS TA, a 22G Franseen needle is most commonly used, with the 25G needle reserved for lesions at difficult locations like in the uncinate process. All attempts are made to perform EUS TA from the duodenal station rather than from the gastric station to avoid needle track seeding. During the needle pass, the fanning technique and wet-suction technique are routinely used. Three passes with a macroscopic examination of the sampled tissue for material adequacy are routinely performed. ROSE is usually reserved in case of previous inconclusive results during a repeat EUS TA.

7. Recent Advancement in EUS TA in Pancreatic Carcinoma

7.1. Role of EUS TA in the Era of Precision Medicine

In oncology, precision medicine comprises diagnoses as well as targeted therapies based on genetic profiles, host factors, and environmental factors. In PDAC, precision medicine is rapidly evolving, and in the era of next-generation sequencing (NGS), in which a relatively limited amount of tissue sample can be successfully analyzed for the detection of genetic alterations, EUS TA plays a major role. Such actionable molecular changes can be seen in about one-fourth of PDAC which can be targeted with precision medicine [129]. The detection of actionable molecular alterations has led to the development of various drugs acting on one or multiple molecular pathways, like the KRAS and DNA mismatch repair (MMR) pathway, and studies have shown better overall survival when patients are treated with matched therapy (n = 143; 2.58 years vs. 1.51 years; hazard ratio (HR) of 0.42 (95%CI: 0.26–0.68), p < 0.001) [130]. Furthermore, other biomarker-based therapeutic agents are also showing promising results in clinical trials (e.g., Pembrolizumab in refractory PDAC with MSH-H/dMMR or TMB—high status) [131]. Thus, the role of adequate tissue acquisition has expanded like never before, reemphasizing the various factors affecting diagnostic adequacy. In a study by Bang JY et al., EUS FNB with a 22G Franseen needle produces a better histological core with the maintenance of tissue architecture for molecular profiling compared to an EUS FNB needle [132]. In a retrospective study, EUS FNB with a 22G Franseen needle is shown to be superior to FNA for tissue adequacy to assess microsatellite instability (88.9% vs. 35.7%, p =  0.03) [133]. In a recent randomized trial among 33 patients using a 22G Franseen needle with the fanning technique and stylet pull maneuver, no significant difference was found in terms of diagnostic adequacy, blood contamination, adequacy, and concentration of extracted DNA and RNA when the patients were randomized into two passes vs. three passes [134]. Recent NCCN guidelines recommend germline testing in all cases of PDAC and molecular analyses for locally advanced and metastatic cases [32]. Similarly, the American Society of Clinical Oncology (ASCO) also encourages early biomarker testing in PDAC patients who are likely to be candidates for precision-medicine-based targeted therapy after first-line chemotherapy [131]. Several other targets are underway for the development of new therapeutics. In the near future, the role of EUS FNB in precision medicine will be further explored, not only for tissue diagnosis but also for molecular profiling to improve overall survival in patients with PDAC.

7.2. Role of Artificial Intelligence in EUS for Pancreatic Carcinoma

Although artificial intelligence (AI) has an expanding horizon in the field of gastrointestinal endoscopy, its role in pancreatic EUS is still primitive with limited studies for the early detection of pancreatic cancer. The introduction of neural networks in AI algorithms has led to significant improvements in AI-based diagnoses of pancreatic cancer. Convolutional neural networks (CNNs) have proven to be superior over traditional neural network models like support vector machines (SVMs) due to their better discriminative function, and they are being developed for the regional recognition and classification of images for the detection of pancreatic cancer. Several studies have evaluated the role of AI in EUS for the detection of PDAC, differentiating PDAC from chronic pancreatitis (especially in complex cases in which both entities co-exist), differentiating PDAC from autoimmune pancreatitis (AIP), and the role of AI in EUS TA. For the detection of PDAC, retrospective studies have used SVMs and CAD (computer-aided design) models and have shown promising results (with a diagnostic accuracy, sensitivity, and specificity of 98%, 94.3%, and 99.5% for SVMs, and 87.5, 83.3, and 93.3% for CAD models, respectively) [135,136]. In a systematic review of 11 studies (n = 2292) using various AI-assisted EUS models, the overall diagnostic accuracy, sensitivity, and specificity were 80–97.5%, 83–100%, and 53–99%, respectively [137]. For differentiating PDAC from CP, several models like ANN-based digital image analyses, extended neural network (ENN)-based EUS-elastography, CAD, self-learning ANN models, and SVM predictive models have shown promising results, though most of these studies are small. In larger, multicentric prospective studies, ANN-assisted EUS-elastography models have shown an 84.3% testing accuracy and more than 90% training accuracy [138]. High values of sensitivity, specificity, and PPV were shown to differentiate PDAC from CP in another prospective study using an ANN-based model with contrast-enhanced EUS [36]. In a recent systematic review and meta-analysis, various algorithms were used for the detection of pancreatic cancer, like deep learning (DL) and artificial neural networks (ANNs). Among the five high-quality studies included in this meta-analysis, the pooled sensitivity and specificity for the AI-assisted detection of pancreatic cancer were 93% and 92%, respectively [139]. In another recent systematic review and meta-analysis of 10 studies (n = 1871), AI had promising results (with sensitivity, specificity, AUROC, and diagnostic OR values of 92%, 90%, 0.95, and 128.9, respectively) for the detection of pancreatic carcinoma. In this study, both ANNs and CNNs had a high diagnostic accuracy, but CNNs were not the best for the detection of pancreatic cancer [140]. More large prospective studies are needed to evaluate the role of EUS in differentiating PDAC from AIP. There are noteworthy limitations of AI-based models, like the lack of standardization for the quality of data; information bias arising due to a lack of diversity of data sources; poor-quality studies with methodological flaws; and the lack of transparent reporting. Apart from these, there are always concerns related to ethical issues and the ‘black box’ problem, in which the reasoning of the algorithm used by AI is not clear to clinicians. Despite these concerns, the use of AI as an adjunctive tool with EUS for diagnosis of PDAC, in form of detection of lesion, and AI-guided TA is likely to expand in near future. However, more large multicentric high-quality trials are needed. Until then, AI should serve as a ‘second set of eyes’ for endo-sonologists [141].

7.3. Role of Organoid Technology in the Diagnosis of PDAC

As PDAC is a phenotypically and genomically heterogeneous tumor, it is difficult to study the tumor behavior and treatment response ex vivo. EUS TA-derived samples have been used for developing pre-clinical models for human PDAC, which are as follows: patient-derived cells (PDCs), patient-derived tumor xenografts (PDTXs), and patient-derived organoids (PDOs) [142]. The results of PDTXs were not encouraging due to the lack of availability of a sufficient number of cells or tissue; additionally, they were more time-consuming and economically challenging. On the other hand, organoids are three-dimensional reconstructed patient-derived cancer cells that retain the genomic and transcriptomic profile of the primary tumor and can be maintained in vitro. Organoid technology has recently revolutionized the area of cancer research due to its fascinating ability to retain the genetic and phenotypic characteristics of the tumor or the primary organ, thus functionally resembling them. This makes the identification of the PDAC phenotype and therapeutic response to an anticancer drug possible in a controlled laboratory setting. Studies have demonstrated that the response to chemotherapeutic agents in organoids can successfully predict their response in patients [143,144]. This efficacy of the organoid system seems to be dependent upon the composition of the organoid [145]. In a recent feasibility study, authors were able to establish a co-culture using PDOs from a small amount of EUS FNB samples and cancer-associated fibroblasts (CAFs). Limitations like a high risk of contamination (blood as well as benign cells), compromising the yield of tissue available, the suboptimal number of needle passes, and unknown histopathological diagnoses before EUS TA can be obviated in future studies to improve the success rate [146].

7.4. Role of Liquid-Based Cytology

Traditionally, smears with a cytological examination, cell block test, and histopathological examination are used for sample preparation. Liquid-based cytology (LBC) has an advantage over conventional smear cytology because of several reasons, like uts higher cellularity, clearer background with fewer artifacts caused by extracellular elements like mucin and necrotic debris, and lower false negative results. Furthermore, LBC can be used for immunohistochemistry (IHC), which can be used for differentiating benign from malignant lesions, understanding tumor biology, and increasing specificity. In a meta-analysis, the EUS-guided conventional smear (CS) technique and LBC technique were compared and nine studies were included for analysis (n = 1308). LBC was analyzed separately based on the method used, i.e., filtration-based and precipitation-based methods. In the absence of ROSE, the precipitation-based LBC technique was found to have a higher accuracy (85.2% vs. 79.7%) and sensitivity (83.6% vs. 79.2%) compared to those of conventional techniques [116]. However, more studies are required before one can advocate LBC for routine clinical use.

7.5. Automated Needles for EUS TA

Most recently, an automated motorized cutting needle was devised by Limaca Medicals (Precision-GITM) for more precise, quicker, and less traumatic tissue acquisition with less tissue fragmentation and blood contamination. A pilot study comparing this automated needle with a fork-tip needle has shown that the motorized needle is associated with a shorter sampling time (p = 0.001) and higher average histologic score (p = 0.002) [147].

8. Conclusions

EUS is currently an indispensable tool in the management of PDAC from detection and tissue diagnosis to the management of various aliments associated with PDAC. Apart from detection, with wider adoption of neo-adjuvant therapies, tissue acquisition for definitive diagnoses has become a part of routine clinical care. The tissue acquisition of histological tumor cores is likely to be a game changer due to the tremendous opportunity afforded by genomic profiling and molecular analyses to deliver precision medicine with better clinical outcomes in the near future.

Author Contributions

A.C.: Drafting manuscript, final approval of manuscript. J.S.: Concept of study, drafting manuscript, critically revising the manuscript, and final approval of manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Younan, G. Pancreas Solid Tumors. Surg. Clin. N. Am. 2020, 100, 565–580. [Google Scholar] [CrossRef] [PubMed]
  2. Abboud, Y.; Samaan, J.S.; Oh, J.; Jiang, Y.; Randhawa, N.; Lew, D.; Ghaith, J.; Pala, P.; Leyson, C.; Watson, R.; et al. Increasing Pancreatic Cancer Incidence in Young Women in the United States: A Population-Based Time-Trend Analysis, 2001–2018. Gastroenterology 2023, 164, 978–989.e6. [Google Scholar] [CrossRef] [PubMed]
  3. Mizrahi, J.D.; Surana, R.; Valle, J.W.; Shroff, R.T. Pancreatic cancer. Lancet 2020, 395, 2008–2020. [Google Scholar] [CrossRef] [PubMed]
  4. Wood, L.D.; Canto, M.I.; Jaffee, E.M.; Simeone, D.M. Pancreatic Cancer: Pathogenesis, Screening, Diagnosis, and Treatment. Gastroenterology 2022, 163, 386–402.e1. [Google Scholar] [CrossRef] [PubMed]
  5. Halbrook, C.J.; Lyssiotis, C.A.; di Magliano, M.P.; Maitra, A. Pancreatic cancer: Advances and challenges. Cell 2023, 186, 1729–1754. [Google Scholar] [CrossRef] [PubMed]
  6. Gaddam, S.; Abboud, Y.; Oh, J.; Samaan, J.S.; Nissen, N.N.; Lu, S.C.; Lo, S.K. Incidence of Pancreatic Cancer by Age and Sex in the US, 2000–2018. JAMA 2021, 326, 2075–2077. [Google Scholar] [CrossRef] [PubMed]
  7. Park, W.; Chawla, A.; O’Reilly, E.M. Pancreatic Cancer: A Review. JAMA J. Am. Med. Assoc. 2021, 326, 851–862. [Google Scholar] [CrossRef] [PubMed]
  8. Varadarajulu, S.; Bang, J.Y. Role of Endoscopic Ultrasonography and Endoscopic Retrograde Cholangiopancreatography in the Clinical Assessment of Pancreatic Neoplasms. Surg. Oncol. Clin. N. Am. 2016, 25, 255–272. [Google Scholar] [CrossRef]
  9. Yousaf, M.N.; Chaudhary, F.S.; Ehsan, A.; Suarez, A.L.; Muniraj, T.; Jamidar, P.; Aslanian, H.R.; Farrell, J.J. Endoscopic ultrasound (EUS) and the management of pancreatic cancer. BMJ Open Gastroenterol. 2020, 7, e000408. [Google Scholar] [CrossRef]
  10. Kitano, M.; Yoshida, T.; Itonaga, M.; Tamura, T.; Hatamaru, K.; Yamashita, Y. Impact of endoscopic ultrasonography on diagnosis of pancreatic cancer. J. Gastroenterol. 2019, 54, 19–32. [Google Scholar] [CrossRef]
  11. Müller, M.F.; Meyenberger, C.; Bertschinger, P.; Schaer, R.; Marincek, B. Pancreatic tumors: Evaluation with endoscopic US, CT, and MR imaging. Radiology 1994, 190, 745–751. [Google Scholar] [CrossRef] [PubMed]
  12. Sakamoto, H.; Kitano, M.; Suetomi, Y.; Maekawa, K.; Takeyama, Y.; Kudo, M. Utility of Contrast-Enhanced Endoscopic Ultrasonography for Diagnosis of Small Pancreatic Carcinomas. Ultrasound Med. Biol. 2008, 34, 525–532. [Google Scholar] [CrossRef] [PubMed]
  13. Yamaguchi, K.; Okusaka, T.; Shimizu, K.; Furuse, J.; Ito, Y.; Hanada, K.; Shimosegawa, T.; Okazaki, K. Clinical practice guidelines for pancreatic cancer 2016 from the Japan pancreas society a synopsis. Pancreas 2017, 46, 595–604. [Google Scholar] [CrossRef] [PubMed]
  14. Krishna, S.G.; Rao, B.B.; Ugbarugba, E.; Shah, Z.K.; Blaszczak, A.; Hinton, A.; Conwell, D.L.; Hart, P.A. Diagnostic performance of endoscopic ultrasound for detection of pancreatic malignancy following an indeterminate multidetector CT scan: A systemic review and meta-analysis. Surg. Endosc. 2017, 31, 4558–4567. [Google Scholar] [CrossRef] [PubMed]
  15. A Overbeek, K.; Levink, I.J.M.; Koopmann, B.D.M.; Harinck, F.; Konings, I.C.A.W.; Ausems, M.G.E.M.; Wagner, A.; Fockens, P.; van Eijck, C.H.; Koerkamp, B.G.; et al. Long-term yield of pancreatic cancer surveillance in high-risk individuals. Gut 2022, 71, 1152–1160. [Google Scholar] [CrossRef] [PubMed]
  16. Yang, A.; Guo, T.; Xu, T.; Zhang, S.; Lai, Y.; Wu, X.; Wu, D.; Feng, Y.; Jiang, Q.; Wang, Q.; et al. The role of EUS in diagnosing focal autoimmune pancreatitis and differentiating it from pancreatic cancer. Endosc. Ultrasound 2021, 10, 280–287. [Google Scholar] [CrossRef] [PubMed]
  17. Izumi, Y.; Hanada, K.; Okazaki, A.; Minami, T.; Hirano, N.; Ikemoto, J.; Kanemitsu, K.; Nakadoi, K.; Shishido, T.; Katamura, Y.; et al. Endoscopic ultrasound findings and pathological features of pancreatic carcinoma in situ. Endosc. Int. Open 2019, 7, E585–E593. [Google Scholar] [CrossRef]
  18. Yang, R.B.; Lu, M.P.; Qian, X.X.; Chen, J.; Li, L.; Wang, J.W.; Zhang, Y. Diagnostic accuracy of EUS and CT of vascular invasion in pancreatic cancer: A systematic review. J. Cancer Res. Clin. Oncol. 2014, 140, 2077–2086. [Google Scholar] [CrossRef]
  19. Kamata, K.; Nakai, A.; Hyodo, T.; Chikugo, T.; Hara, A.; Otsuka, Y.; Tanaka, H.; Yoshikawa, T.; Ishikawa, R.; Okamoto, A.; et al. Utility of contrast-enhanced harmonic EUS for diagnosis of portal vein invasion by pancreatic cancer. Endosc. Ultrasound 2022, 11, 401–406. [Google Scholar] [CrossRef]
  20. Sugiyama, M.; Hagi, H.; Atomi, Y.; Saito, M. Diagnosis of portal venous invasion by pancreatobiliary carcinoma: Value of endoscopic ultrasonography. Abdom. Imaging 1997, 22, 434–438. [Google Scholar] [CrossRef]
  21. Fujii, Y.; Matsumoto, K.; Kato, H.; Saragai, Y.; Takada, S.; Mizukawa, S.; Muro, S.; Uchida, D.; Tomoda, T.; Horiguchi, S.; et al. Diagnostic Ability of Convex-Arrayed Endoscopic Ultrasonography for Major Vascular Invasion in Pancreatic Cancer. Clin. Endosc. 2019, 52, 479–485. [Google Scholar] [CrossRef] [PubMed]
  22. Bispo, M.; Marques, S.; Rio-Tinto, R.; Fidalgo, P.; Devière, J. The Role of Endoscopic Ultrasound in Pancreatic Cancer Staging in the Era of Neoadjuvant Therapy and Personalised Medicine. GE-Port. J. Gastroenterol. 2021, 28, 111–120. [Google Scholar] [CrossRef] [PubMed]
  23. Nawaz, H.; Fan, C.Y.; Kloke, J.; Khalid, A.; McGrath, K.; Landsittel, D.; I Papachristou, G. Performance Characteristics of Endoscopic Ultrasound in the Staging of Pancreatic Cancer: A Meta-Analysis. JOP 2013, 14, 484–497. [Google Scholar] [CrossRef] [PubMed]
  24. Kurita, A.; Kodama, Y.; Nakamoto, Y.; Isoda, H.; Minamiguchi, S.; Yoshimura, K.; Kuriyama, K.; Sawai, Y.; Uza, N.; Hatano, E.; et al. Impact of EUS-FNA for preoperative para-aortic lymph node staging in patients with pancreatobiliary cancer. Gastrointest. Endosc. 2016, 84, 467–475.e1. [Google Scholar] [CrossRef] [PubMed]
  25. Catalano, M.F.; Sivak, M.V.; Rice, T.; Gragg, L.A.; Van Dam, J. Endosonographic features predictive of lymph node metastasis. Gastrointest. Endosc. 1994, 40, 442–446. [Google Scholar] [CrossRef] [PubMed]
  26. Okasha, H.; Wifi, M.-N.; Awad, A.; Abdelfatah, Y.; Abdelfatah, D.; El-Sawy, S.; Alzamzamy, A.; Abou-Elenin, S.; Abou-Elmagd, A.; ElHusseiny, R.; et al. Role of EUS in detection of liver metastasis not seen by computed tomography or magnetic resonance imaging during staging of pancreatic, gastrointestinal, and thoracic malignancies. Endosc. Ultrasound 2021, 10, 344–354. [Google Scholar] [CrossRef] [PubMed]
  27. Singh, P.; Mukhopadhyay, P.; Bhatt, B.; Patel, T.; Kiss, A.; Gupta, R.; Bhat, S.; Erickson, R. Endoscopic Ultrasound Versus CT Scan for Detection of the Metastases to the Liver Results of a Prospective Comparative Study. J. Clin. Gastroenterol. 2009, 43, 367–373. [Google Scholar] [CrossRef] [PubMed]
  28. Nguyen, P.T.; Chang, K.J. EUS in the detection of ascites and EUS-guided paracentesis. Gastrointest. Endosc. 2001, 54, 336–339. [Google Scholar] [CrossRef]
  29. Siddappa, P.K.; Jain, N.; Agarwal, N.K.; Jain, M.; Lamba, G.S. Endoscopic Ultrasound-Guided Random Omental Fine Needle Aspiration: A Novel Technique for the Diagnosis of Peritoneal Carcinomatosis. Clin. Endosc. 2020, 53, 594–599. [Google Scholar] [CrossRef]
  30. Rustagi, T.; Gleeson, F.C.; Chari, S.T.; Lehrke, H.D.; Takahashi, N.; Malikowski, T.M.; Abu Dayyeh, B.K.; Chandrasekhara, V.; Iyer, P.G.; Kendrick, M.L.; et al. Safety, Diagnostic Accuracy, and Effects of Endoscopic Ultrasound Fine-Needle Aspiration on Detection of Extravascular Migratory Metastases. Clin. Gastroenterol. Hepatol. 2019, 17, 2533–2540.e1. [Google Scholar] [CrossRef]
  31. James, P.D.; Meng, Z.W.; Zhang, M.; Belletrutti, P.J.; Mohamed, R.; Ghali, W.; Roberts, D.J.; Martel, G.; Heitman, S.J. The incremental benefit of EUS for identifying unresectable disease among adults with pancreatic adenocarcinoma: A meta-analysis. PLoS ONE 2017, 12, e0173687. [Google Scholar] [CrossRef] [PubMed]
  32. NCCN Guidelines Version 2.2023 Pancreatic Adenocarcinoma Continue NCCN Guidelines Version 2.2023 Pancreatic Adenocarcinoma - Google Search. Available online: https://www.google.com/search?client=safari&rls=en&q=NCCN+Guidelines+Version+2.2023+Pancreatic+Adenocarcinoma+Continue+NCCN+Guidelines+Version+2.2023+Pancreatic+Adenocarcinoma&ie=UTF-8&oe=UTF-8#ip=1 (accessed on 20 December 2023).
  33. Conroy, T.; Pfeiffer, P.; Vilgrain, V.; Lamarca, A.; Seufferlein, T.; O’reilly, E.; Hackert, T.; Golan, T.; Prager, G.; Haustermans, K.; et al. Pancreatic cancer: ESMO Clinical Practice Guideline for diagnosis, treatment and follow-up. Ann. Oncol. 2023, 34, 987–1002. [Google Scholar] [CrossRef] [PubMed]
  34. Saftoiu, A.; Vilmann, P.; Bhutani, M. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma. Endosc. Ultrasound 2016, 5, 368–372. [Google Scholar] [CrossRef] [PubMed]
  35. Mei, S.; Wang, M.; Sun, L. Contrast-Enhanced EUS for Differential Diagnosis of Pancreatic Masses: A Meta-Analysis. Gastroenterol. Res. Pract. 2019, 2019, 1670183. [Google Scholar] [CrossRef] [PubMed]
  36. Săftoiu, A.; Vilmann, P.; Dietrich, C.F.; Iglesias-Garcia, J.; Hocke, M.; Seicean, A.; Ignee, A.; Hassan, H.; Streba, C.T.; Ioncică, A.M.; et al. Quantitative contrast-enhanced harmonic EUS in differential diagnosis of focal pancreatic masses (with videos). Gastrointest. Endosc. 2015, 82, 59–69. [Google Scholar] [CrossRef] [PubMed]
  37. Wang, Y.; Yan, K.; Fan, Z.; Sun, L.; Wu, W.; Yang, W. Contrast-Enhanced Ultrasonography of Pancreatic Carcinoma: Correlation with Pathologic Findings. Ultrasound Med. Biol. 2016, 42, 891–898. [Google Scholar] [CrossRef] [PubMed]
  38. Imazu, H.; Uchiyama, Y.; Matsunaga, K.; Ikeda, K.-I.; Kakutani, H.; Sasaki, Y.; Sumiyama, K.; Ang, T.L.; Omar, S.; Tajiri, H. Contrast-enhanced harmonic EUS with novel ultrasonographic contrast (Sonazoid) in the preoperative T-staging for pancreaticobiliary malignancies. Scand. J. Gastroenterol. 2010, 45, 732–738. [Google Scholar] [CrossRef] [PubMed]
  39. Emori, T.; Nuta, J.; Kawaji, Y.; Tamura, T.; Hatamaru, K.; Itonaga, M.; Yamashita, Y.; Ashida, R.; Shimokawa, T.; Koike, M.; et al. Value of contrast-enhanced harmonic endoscopic ultrasound for diagnosing hepatic metastases of pancreatic cancer: A prospective study. J. Gastroenterol. Hepatol. 2021, 36, 3402–3409. [Google Scholar] [CrossRef]
  40. Minaga, K.; Kitano, M.; Nakai, A.; Omoto, S.; Kamata, K.; Yamao, K.; Takenaka, M.; Tsurusaki, M.; Chikugo, T.; Matsumoto, I.; et al. Improved detection of liver metastasis using Kupffer-phase imaging in contrast-enhanced harmonic EUS in patients with pancreatic cancer (with video). Gastrointest. Endosc. 2021, 93, 433–441. [Google Scholar] [CrossRef]
  41. Miyata, T.; Kitano, M.; Omoto, S.; Kadosaka, K.; Kamata, K.; Imai, H.; Sakamoto, H.; Nisida, N.; Harwani, Y.; Murakami, T.; et al. Contrast-enhanced harmonic endoscopic ultrasonography for assessment of lymph node metastases in pancreatobiliary carcinoma. World J. Gastroenterol. 2016, 22, 3381–3391. [Google Scholar] [CrossRef]
  42. Facciorusso, A.; Crinò, S.F.; Gkolfakis, P.; Ramai, D.; Mangiavillano, B.; Castillo, J.L.; Chandan, S.; Mohan, B.P.; D’errico, F.; Decembrino, F.; et al. Needle Tract Seeding after Endoscopic Ultrasound Tissue Acquisition of Pancreatic Lesions: A Systematic Review and Meta-Analysis. Diagnostics 2022, 12, 2113. [Google Scholar] [CrossRef] [PubMed]
  43. Kuo, Y.-T.; Chu, Y.-L.; Wong, W.-F.; Han, M.-L.; Chen, C.-C.; Jan, I.-S.; Cheng, W.-C.; Shun, C.-T.; Tsai, M.-C.; Cheng, T.-Y.; et al. Randomized trial of contrast-enhanced harmonic guidance versus fanning technique for EUS-guided fine-needle biopsy sampling of solid pancreatic lesions. Gastrointest. Endosc. 2023, 97, 732–740. [Google Scholar] [CrossRef] [PubMed]
  44. Iglesias-Garcia, J.; de la Iglesia-Garcia, D.; Lariño-Noia, J.; Dominguez-Muñoz, J.E. Endoscopic Ultrasound (EUS) Guided Elastography. Diagnostics 2023, 13, 1686. [Google Scholar] [CrossRef] [PubMed]
  45. Iglesias–Garcia, J.; Larino–Noia, J.; Abdulkader, I.; Forteza, J.; Dominguez–Munoz, J.E. Quantitative Endoscopic Ultrasound Elastography: An Accurate Method for the Differentiation of Solid Pancreatic Masses. Gastroenterology 2010, 139, 1172–1180. [Google Scholar] [CrossRef] [PubMed]
  46. Iglesias-Garcia, J.; Lindkvist, B.; Lariño-Noia, J.; Abdulkader-Nallib, I.; Dominguez-Muñoz, J.E. Differential diagnosis of solid pancreatic masses: Contrast-enhanced harmonic (CEH-EUS), quantitative-elastography (QE-EUS), or both? United Eur. Gastroenterol J. 2017, 5, 236–246. [Google Scholar] [CrossRef] [PubMed]
  47. Mei, M.; Ni, J.; Liu, D.; Jin, P.; Sun, L. EUS elastography for diagnosis of solid pancreatic masses: A meta-analysis. Gastrointest. Endosc. 2013, 77, 578–589. [Google Scholar] [CrossRef] [PubMed]
  48. Facciorusso, A.; Crinò, S.F.; Ramai, D.; Madhu, D.; Fugazza, A.; Carrara, S.; Spadaccini, M.; Mangiavillano, B.; Gkolfakis, P.; Mohan, B.P.; et al. Comparative diagnostic performance of different techniques for EUS-guided fine-needle biopsy sampling of solid pancreatic masses: A network meta-analysis. Gastrointest. Endosc. 2023, 97, 839–848.e5. [Google Scholar] [CrossRef] [PubMed]
  49. Abboud, Y.; Kim, K.; Samaan, J.S.; Chen, C.; Lew, D.; Ghaith, J.; Caldera, W.; El Helou, M.O.; Park, K.H.; Liu, Q.; et al. Endoscopic Ultrasound Guided Shear Wave Elastography Is Safe With High Feasibility and Reproducibility When Used in the Pancreas: Findings From a Prospective Cohort. Pancreas 2023, 52, e115–e120. [Google Scholar] [CrossRef]
  50. Versteijne, E.; van Dam, J.L.; Suker, M.; Janssen, Q.P.; Groothuis, K.; Akkermans-Vogelaar, J.M.; Besselink, M.G.; Bonsing, B.A.; Buijsen, J.; Busch, O.R.; et al. Neoadjuvant Chemoradiotherapy Versus Upfront Surgery for Resectable and Borderline Resectable Pancreatic Cancer: Long-Term Results of the Dutch Randomized PREOPANC Trial. J. Clin. Oncol. 2022, 40, 1220–1230. [Google Scholar] [CrossRef]
  51. Volmar, K.E.; Vollmer, R.T.; Jowell, P.S.; Nelson, R.C.; Xie, H.B.; Durham, P. Pancreatic FNA in 1000 cases: A comparison of imaging modalities. Gastrointest. Endosc. 2005, 61, 854–861. [Google Scholar] [CrossRef]
  52. Imaoka, H.; Sasaki, M.; Hashimoto, Y.; Watanabe, K.; Ikeda, M. New Era of Endoscopic Ultrasound-Guided Tissue Acquisition: Next-Generation Sequencing by Endoscopic Ultrasound-Guided Sampling for Pancreatic Cancer. J. Clin. Med. 2019, 8, 1173. [Google Scholar] [CrossRef] [PubMed]
  53. Song, T.J.; Kim, J.H.; Lee, S.S.; Eum, J.B.; Moon, S.H.; Park, D.H.; Seo, D.W.; Lee, S.K.; Jang, S.J.; Yun, S.C.; et al. The Prospective Randomized, Controlled Trial of Endoscopic Ultrasound-Guided Fine-Needle Aspiration Using 22G and 19G Aspiration Needles for Solid Pancreatic or Peripancreatic Masses. Am. J. Gastroenterol. 2010, 105, 1739–1745. [Google Scholar] [CrossRef] [PubMed]
  54. Laquière, A.; Lefort, C.; Maire, F.; Aubert, A.; Gincul, R.; Prat, F.; Grandval, P.; Croizet, O.; Boulant, J.; Vanbiervliet, G.; et al. 19 G nitinol needle versus 22 G needle for transduodenal endoscopic ultrasound-guided sampling of pancreatic solid masses: A randomized study. Endoscopy 2019, 51, 436–443. [Google Scholar] [CrossRef] [PubMed]
  55. Madhoun, M.F.; Wani, S.B.; Rastogi, A.; Early, D.; Gaddam, S.; Tierney, W.M.; Maple, J.T. The diagnostic accuracy of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions: A meta-analysis. Endoscopy 2013, 45, 86–92. [Google Scholar] [CrossRef] [PubMed]
  56. Guedes, H.G.; de Moura, D.T.H.; Duarte, R.B.; Cordero, M.A.C.; dos Santos, M.E.L.; Cheng, S.; Matuguma, S.E.; Chaves, D.M.; Bernardo, W.M.; de Moura, E.G.H. A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis. Clinics 2018, 73, e261. [Google Scholar] [CrossRef] [PubMed]
  57. Affolter, K.E.; Schmidt, R.L.; Matynia, A.P.; Adler, D.G.; Factor, R.E. Needle Size Has Only a Limited Effect on Outcomes in EUS-Guided Fine Needle Aspiration: A Systematic Review and Meta-Analysis. Dig. Dis. Sci. 2013, 58, 1026–1034. [Google Scholar] [CrossRef] [PubMed]
  58. Polkowski, M.; Jenssen, C.C.; Kaye, P.V.; Carrara, S.; Deprez, P.; Ginès, A.; Fernández-Esparrach, G.G.; Eisendrath, P.; Aithal, G.P.; Arcidiacono, P.P.; et al. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline—March 2017. Endoscopy 2017, 49, 989–1006. [Google Scholar] [CrossRef]
  59. Bush, N.; Rana, S.S. Endoscopic Ultrasound Biopsy Needle. J. Dig. Endosc. 2022, 13, 240–242. [Google Scholar] [CrossRef]
  60. Bang, J.Y.; Hebert-Magee, S.; Trevino, J.; Ramesh, J.; Varadarajulu, S. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest. Endosc. 2012, 76, 321–327. [Google Scholar] [CrossRef]
  61. Cheng, B.; Zhang, Y.; Chen, Q.; Sun, B.; Deng, Z.; Shan, H.; Dou, L.; Wang, J.; Li, Y.; Yang, X.; et al. Analysis of Fine-Needle Biopsy vs Fine-Needle Aspiration in Diagnosis of Pancreatic and Abdominal Masses: A Prospective, Multicenter, Randomized Controlled Trial. Clin. Gastroenterol. Hepatol. 2018, 16, 1314–1321. [Google Scholar] [CrossRef]
  62. Van Riet, P.A.; Erler, N.S.; Bruno, M.J.; Cahen, D.L. Comparison of fine-needle aspiration and fine-needle biopsy devices for endoscopic ultrasound-guided sampling of solid lesions: A systemic review and meta-analysis. Endoscopy 2021, 53, 411–423. [Google Scholar] [CrossRef] [PubMed]
  63. Renelus, B.D.; Jamorabo, D.S.; Boston, I.; Briggs, W.M.; Poneros, J.M. Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis. Clin. Endosc. 2021, 54, 261–268. [Google Scholar] [CrossRef] [PubMed]
  64. Karsenti, D.; Palazzo, L.; Perrot, B.; Zago, J.; Lemaistre, A.-I.; Cros, J.; Napoléon, B. 22G Acquire vs. 20G Procore needle for endoscopic ultrasound-guided biopsy of pancreatic masses: A randomized study comparing histologic sample quantity and diagnostic accuracy. Endoscopy 2020, 52, 747–753. [Google Scholar] [CrossRef] [PubMed]
  65. Kurita, A.; Yasukawa, S.; Zen, Y.; Yoshimura, K.; Ogura, T.; Ozawa, E.; Okabe, Y.; Asada, M.; Nebiki, H.; Shigekawa, M.; et al. Comparison of a 22-gauge Franseen-tip needle with a 20-gauge forward-bevel needle for the diagnosis of type 1 autoimmune pancreatitis: A prospective, randomized, controlled, multicenter study (COMPAS study). Gastrointest. Endosc. 2019, 91, 373–381.e2. [Google Scholar] [CrossRef]
  66. Ashat, M.; Klair, J.S.; Rooney, S.L.; Vishal, S.J.; Jensen, C.; Sahar, N.; Murali, A.R.; El-Abiad, R.; Gerke, H. Randomized controlled trial comparing the Franseenneedle with the Fork-tip needle for EUS-guidedfine-needle biopsy. Gastrointest. Endosc. 2021, 23, 140–150. [Google Scholar]
  67. Bang, J.Y.; Hebert-Magee, S.; Navaneethan, U.; Hasan, M.K.; Hawes, R.; Varadarajulu, S. Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions. Gastrointest. Endosc. 2018, 87, 1432–1438. [Google Scholar] [CrossRef]
  68. Mohan, B.P.; Shakhatreh, M.; Garg, R.; Asokkumar, R.; Jayaraj, M.; Ponnada, S.; Navaneethan, U.; Adler, D.G. Comparison of Franseen and fork-tip needles for EUS-guided fine-needle biopsy of solid mass lesions: A systematic review and meta-analysis. Endosc. Ultrasound 2019, 8, 382–391. [Google Scholar] [CrossRef]
  69. Gkolfakis, P.; Crinò, S.F.; Tziatzios, G.; Ramai, D.; Papaefthymiou, A.; Papanikolaou, I.S.; Triantafyllou, K.; Arvanitakis, M.; Lisotti, A.; Fusaroli, P.; et al. Systematic review and meta-analysis Comparative diagnostic performance of end-cutting fine-needle biopsy needles for EUS tissue sampling of solid pancreatic masses: A network meta-analysis. Gastrointest. Endosc. 2022, 95, 1067–1077. [Google Scholar] [CrossRef]
  70. Kudo, T.; Kawakami, H.; Hayashi, T.; Yasuda, I.; Mukai, T.; Inoue, H.; Katanuma, A.; Kawakubo, K.; Ishiwatari, H.; Doi, S.; et al. High and low negative pressure suction techniques in EUS-guided fine-needle tissue acquisition by using 25-gauge needles: A multicenter, prospective, randomized, controlled trial. Gastrointest. Endosc. 2014, 80, 1030–1037.e1. [Google Scholar] [CrossRef]
  71. Tarantino, I.; Di Mitri, R.; Fabbri, C.; Pagano, N.; Barresi, L.; Granata, A.; Liotta, R.; Mocciaro, F.; Maimone, A.; Baccarini, P.; et al. Is diagnostic accuracy of fine needle aspiration on solid pancreatic lesions aspiration-related? A multicentre randomised trial. Dig. Liver Dis. 2014, 46, 523–526. [Google Scholar] [CrossRef]
  72. Lee, J.K.; Choi, J.H.; Lee, K.H.; Kim, K.M.; Shin, J.U.; Lee, J.K.; Lee, K.T.; Jang, K.-T. A prospective, comparative trial to optimize sampling techniques in EUS-guided FNA of solid pancreatic masses. Gastrointest. Endosc. 2013, 77, 745–751. [Google Scholar] [CrossRef] [PubMed]
  73. Attam, R.; Arain, M.A.; Bloechl, S.J.; Trikudanathan, G.; Munigala, S.; Bakman, Y.; Singh, M.; Wallace, T.; Henderson, J.B.; Catalano, M.F.; et al. “Wet suction technique (WEST)”: A novel way to enhance the quality of EUS-FNA aspirate. Results of a prospective, single-blind, randomized, controlled trial using a 22-gauge needle for EUS-FNA of solid lesions. Gastrointest. Endosc. 2015, 81, 1401–1407. [Google Scholar] [CrossRef] [PubMed]
  74. Villa, N.A.; Berzosa, M.; Wallace, M.B.; Raijman, I. Endoscopic ultrasound-guided fine needle aspiration: The wet suction technique. Endosc. Ultrasound 2016, 5, 17–20. [Google Scholar] [CrossRef] [PubMed]
  75. Berzosa, M.; Uthamaraj, S.; Dragomir-Daescu, D.; Raijman, I.; Qumseya, B.J.; Raimondo, M.; Woodward, T.A.; Wallace, M.B. Mo1395 EUS-FNA Wet vs. Dry Suction Techniques; a Proof of Concept Study on How a Column of Water Enhances Tissue Aspiration. Gastrointest. Endosc. 2014, 79, AB421–AB422. [Google Scholar] [CrossRef]
  76. Adler, D.; Ramai, D.; Singh, J.; Kani, T.; Barakat, M.; Chandan, S.; Brooks, O.; Ofosu, A.; Khan, S.; Dhindsa, B.; et al. Wet- versus dry-suction techniques for EUS-FNA of solid lesions: A systematic review and meta-analysis. Endosc. Ultrasound 2021, 10, 319–324. [Google Scholar] [CrossRef] [PubMed]
  77. Saxena, P.; El Zein, M.; Stevens, T.; Abdelgelil, A.; Besharati, S.; Messallam, A.; Kumbhari, V.; Azola, A.; Brainard, J.; Shin, E.J.; et al. Stylet slow-pull versus standard suction for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic lesions: A multicenter randomized trial. Endoscopy 2018, 50, 497–504. [Google Scholar] [CrossRef] [PubMed]
  78. Kin, T.; Katanuma, A.; Yane, K.; Takahashi, K.; Osanai, M.; Takaki, R.; Matsumoto, K.; Gon, K.; Matsumori, T.; Tomonari, A.; et al. Diagnostic ability of EUS-FNA for pancreatic solid lesions with conventional 22-gauge needle using the slow pull technique: A prospective study. Scand. J. Gastroenterol. 2015, 50, 900–907. [Google Scholar] [CrossRef]
  79. Nakai, Y.; Isayama, H.; Chang, K.J.; Yamamoto, N.; Hamada, T.; Uchino, R.; Mizuno, S.; Miyabayashi, K.; Yamamoto, K.; Kawakubo, K.; et al. Slow Pull Versus Suction in Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Solid Masses. Dig. Dis. Sci. 2014, 59, 1578–1585. [Google Scholar] [CrossRef]
  80. Bansal, R.K.; Puri, R. EUS-Guided FNA: Tips and Tricks. J. Dig. Endosc. 2020, 11, 099–105. [Google Scholar] [CrossRef]
  81. Giri, S.; Afzalpurkar, S.; Angadi, S.; Marikanty, A.; Sundaram, S. Comparison of suction techniques for EUS-guided tissue acquisition: Systematic review and network meta-analysis of randomized controlled trials. Endosc. Int. Open 2023, 11, E703–E711. [Google Scholar] [CrossRef]
  82. Bang, J.Y.; Magee, S.H.; Ramesh, J.; Trevino, J.M.; Varadarajulu, S. Randomized trial comparing fanning with standard technique for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic mass lesions. Endoscopy 2013, 45, 445–450. [Google Scholar] [CrossRef] [PubMed]
  83. Lee, J.M.; Lee, H.S.; Hyun, J.J.; Lee, J.M.; Yoo, I.K.; Kim, S.H.; Choi, H.S.; Kim, E.S.; Keum, B.; Seo, Y.S.; et al. Slow-Pull Using a Fanning Technique Is More Useful Than the Standard Suction Technique in EUS-Guided Fine Needle Aspiration in Pancreatic Masses. Gut Liver 2018, 12, 360–366. [Google Scholar] [CrossRef] [PubMed]
  84. Mukai, S.; Itoi, T.; Ashida, R.; Tsuchiya, T.; Ikeuchi, N.; Kamada, K.; Tanaka, R.; Umeda, J.; Tonozuka, R.; Fukutake, N.; et al. Multicenter, prospective, crossover trial comparing the door-knocking method with the conventional method for EUS-FNA of solid pancreatic masses (with videos). Gastrointest. Endosc. 2016, 83, 1210–1217. [Google Scholar] [CrossRef] [PubMed]
  85. Uehara, H.; Sueyoshi, H.; Takada, R.; Fukutake, N.; Katayama, K.; Ashida, R.; Ioka, T.; Takenaka, A.; Nagata, S.; Tomita, Y. Optimal number of needle passes in endoscopic ultrasound-guided fine needle aspiration for pancreatic lesions. Pancreatology 2015, 15, 392–396. [Google Scholar] [CrossRef] [PubMed]
  86. Paik, W.H.; Choi, J.H.; Park, Y.; Lee, J.B.; Park, D.H. Optimal Techniques for EUS-Guided Fine-Needle Aspiration of Pancreatic Solid Masses at Facilities without On-Site Cytopathology: Results from Two Prospective Randomised Trials. J. Clin. Med. 2021, 10, 4662. [Google Scholar] [CrossRef] [PubMed]
  87. Jin, Z.-D.; Wang, K.-X.; Zhou, W.; Li, S.-Y.; Jiang, H.; Gao, L.; Li, J.; Kong, X.-Y.; Yang, L.; Fang, A.-Q. Optimal number of needle passes during EUS-guided fine-needle biopsy of solid pancreatic lesions with 22G ProCore needles and different suction techniques: A randomized controlled trial. Endosc. Ultrasound 2021, 10, 62–70. [Google Scholar] [CrossRef] [PubMed]
  88. Takahashi, K.; Yasuda, I.; Hayashi, N.; Iwashita, T.; Okuno, M.; Mukai, T.; Mabuchi, M.; Adachi, S.; Doi, S.; Imura, J.; et al. EUS-guided fine-needle biopsy sampling of solid pancreatic tumors with 3 versus 12 to-and-fro movements: A multicenter prospective randomized controlled study. Gastrointest. Endosc. 2023, 97, 1092–1099. [Google Scholar] [CrossRef] [PubMed]
  89. Wani, S.; Mullady, D.; Early, D.S.; Rastogi, A.; Collins, B.; Wang, J.F.; Marshall, C.; Sams, S.B.; Yen, R.; Rizeq, M.; et al. The Clinical Impact of Immediate On-Site Cytopathology Evaluation During Endoscopic Ultrasound-Guided Fine Needle Aspiration of Pancreatic Masses: A Prospective Multicenter Randomized Controlled Trial. Am. J. Gastroenterol. 2015, 110, 1429–1439. [Google Scholar] [CrossRef]
  90. Lee, L.S.; Nieto, J.; Watson, R.R.; Hwang, A.L.; Muthusamy, V.R.; Walter, L.; Jajoo, K.; Ryou, M.K.; Saltzman, J.R.; Saunders, M.D.; et al. Randomized non-inferiority trial comparing diagnostic yield of cytopathologist-guided versus seven passes for endoscopic ultrasound-guided fine-needle aspiration of pancreatic masses. Dig. Endosc. 2016, 28, 469–475. [Google Scholar] [CrossRef]
  91. Crinò, S.F.; Di Mitri, R.; Nguyen, N.Q.; Tarantino, I.; de Nucci, G.; Deprez, P.H.; Carrara, S.; Kitano, M.; Shami, V.M.; Fernández-Esparrach, G.; et al. Endoscopic Ultrasound–guided Fine-needle Biopsy With or Without Rapid On-site Evaluation for Diagnosis of Solid Pancreatic Lesions: A Randomized Controlled Non-Inferiority Trial. Gastroenterology 2021, 161, 899–909.e5. [Google Scholar] [CrossRef]
  92. Chen, Y.I.; Chatterjee, A.; Berger, R.; Kanber, Y.; Wyse, J.; Lam, E.; Gan, I.; Auger, M.; Kenshil, S.; Telford, J.; et al. Endoscopic ultrasound (EUS)-guided fine needle biopsy alone vsEUS-guided fine needle aspiration with rapid onsite evaluation in pancreatic lesions: A multicenter randomized trial. Endoscopy. 2022, 54, 4–12. [Google Scholar]
  93. Iwashita, T.; Yasuda, I.; Mukai, T.; Doi, S.; Nakashima, M.; Uemura, S.; Mabuchi, M.; Shimizu, M.; Hatano, Y.; Hara, A.; et al. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: A single-center prospective pilot study (MOSE study). Gastrointest. Endosc. 2015, 81, 177–185. [Google Scholar] [CrossRef] [PubMed]
  94. Kaneko, J.; Ishiwatari, H.; Sasaki, K.; Yasuda, I.; Takahashi, K.; Imura, J.; Iwashita, T.; Uemura, S.; Hatano, Y.; Miyazaki, T.; et al. Macroscopic visible core length can predict the histological sample quantity in endoscopic ultrasound-guided tissue acquisition: Multicenter prospective study. Dig. Endosc. 2022, 34, 622–631. [Google Scholar] [CrossRef] [PubMed]
  95. Chong, C.C.N.; Lakhtakia, S.; Nguyen, N.; Hara, K.; Chan, W.K.; Puri, R.; Almadi, M.A.; Ang, T.L.; Kwek, A.; Yasuda, I.; et al. Endoscopic ultrasound-guided tissue acquisition with or without macroscopic on-site evaluation: Randomized controlled trial. Endoscopy 2020, 52, 856–863. [Google Scholar] [CrossRef] [PubMed]
  96. Yaghoobi, M.; Rahman, M.O.; Chan, B.H.; Far, P.; Mbuagbaw, L.; Thabane, L. Endoscopic ultrasound versus computed tomography in determining the resectability of pancreatic cancer: A diagnostic test accuracy meta-analysis. Saudi J. Gastroenterol. 2020, 26, 113–119. [Google Scholar] [CrossRef] [PubMed]
  97. Lin, L.Z.; Li, F.; Liu, Y.; Xing, L.X.; Du, L.F. Contrast-Enhanced Ultrasound for differential diagnosis of pancreatic mass lesions: A meta-analysis. Med. Ultrason. 2016, 18, 163–169. [Google Scholar] [CrossRef] [PubMed]
  98. Yamashita, Y.; Shimokawa, T.; Napoléon, B.; Fusaroli, P.; Gincul, R.; Kudo, M.; Kitano, M. Value of contrast-enhanced harmonic endoscopic ultrasonography with enhancement pattern for diagnosis of pancreatic cancer: A meta-analysis. Dig. Endosc. 2019, 31, 125–133. [Google Scholar] [CrossRef] [PubMed]
  99. Shin, C.M.; Villa, E. The efficiency of contrast-enhanced endoscopic ultrasound (EUS) combined with EUS elastography for pancreatic cancer diagnosis: A systematic review and meta-analysis. Ultrasonography 2023, 42, 20–30. [Google Scholar] [CrossRef] [PubMed]
  100. Facciorusso, A.; Mohan, B.P.; Crinò, S.F.; Ofosu, A.; Ramai, D.; Lisotti, A.; Chandan, S.; Fusaroli, P. Contrast-enhanced harmonic endoscopic ultrasound-guided fine-needle aspiration versus standard fine-needle aspiration in pancreatic masses: A meta-analysis. Expert Rev. Gastroenterol. Hepatol. 2021, 15, 821–828. [Google Scholar] [CrossRef]
  101. Banafea, O.; Mghanga, F.P.; Zhao, J.; Zhao, R.; Zhu, L. Endoscopic ultrasonography with fine-needle aspiration for histological diagnosis of solid pancreatic masses: A meta-analysis of diagnostic accuracy studies. BMC Gastroenterol. 2016, 16, 108. [Google Scholar] [CrossRef]
  102. Xu, M.-M.; Jia, H.-Y.; Yan, L.-L.; Li, S.-S.; Zheng, Y. Comparison of two different size needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing solid pancreatic lesions. Medicine 2017, 96, e5802. [Google Scholar] [CrossRef]
  103. Tian, G.; Bao, H.; Li, J.; Jiang, T. Systematic Review and Meta-Analysis of Diagnostic Accuracy of Endoscopic Ultrasound (EUS)-Guided Fine-Needle Aspiration (FNA) Using 22-gauge and 25-gauge Needles for Pancreatic Masses. Experiment 2018, 24, 8333–8341. [Google Scholar] [CrossRef] [PubMed]
  104. Yang, Y.; Li, L.; Qu, C.; Liang, S.; Zeng, B.; Luo, Z. Endoscopic ultrasound-guided fine needle core biopsy for the diagnosis of pancreatic malignant lesions: A systematic review and Meta-Analysis. Sci Rep. 2016, 6, 22978. [Google Scholar] [CrossRef] [PubMed]
  105. Hassan, G.M.; Laporte, L.; Paquin, S.C.; Menard, C.; Sahai, A.V.; Mâsse, B.; Trottier, H. Endoscopic Ultrasound Guided Fine Needle Aspiration versus Endoscopic Ultrasound Guided Fine Needle Biopsy for Pancreatic Cancer Diagnosis: A Systematic Review and Meta-Analysis. Diagnostics 2022, 12, 2951. [Google Scholar] [CrossRef] [PubMed]
  106. Bang, J.Y.; Hawes, R.; Varadarajulu, S. A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition. Endoscopy 2015, 48, 339–349. [Google Scholar] [CrossRef] [PubMed]
  107. Li, Z.M.; Liu, W.; Xu, X.M.; Li, P.M. A Meta-Analysis Comparing Endoscopic Ultrasound-guided Fine-needle Aspiration With Endoscopic Ultrasound-guided Fine-needle Biopsy. J. Clin. Gastroenterol. 2022, 56, 668–678. [Google Scholar] [CrossRef] [PubMed]
  108. Facciorusso, A.; Bajwa, H.; Menon, K.; Buccino, V.; Muscatiello, N. Comparison between 22G aspiration and 22G biopsy needles for EUS-guided sampling of pancreatic lesions: A meta-analysis. Endosc. Ultrasound 2020, 9, 167–174. [Google Scholar] [CrossRef] [PubMed]
  109. Facciorusso, A.; Del Prete, V.; Buccino, V.R.; Purohit, P.; Setia, P.; Muscatiello, N. Diagnostic yield of Franseen and Fork-Tip biopsy needles for endoscopic ultrasound-guided tissue acquisition: A meta-analysis. Endosc. Int. Open 2019, 7, E1221–E1230. [Google Scholar] [CrossRef]
  110. Facciorusso, A.; Gkolfakis, P.; Tziatzios, G.; Ramai, D.; Papanikolaou, I.; Triantafyllou, K.; Lisotti, A.; Fusaroli, P.; Mangiavillano, B.; Chandan, S.; et al. Comparison between EUS-guided fine-needle biopsy with or without rapid on-site evaluation for tissue sampling of solid pancreatic lesions: A systematic review and meta-analysis. Endosc. Ultrasound 2022, 11, 458–465. [Google Scholar] [CrossRef]
  111. Kong, F.; Zhu, J.; Kong, X.; Sun, T.; Deng, X.; Du, Y.; Li, Z. Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review. PLoS ONE 2016, 11, e0163056. [Google Scholar] [CrossRef]
  112. Lisotti, A.; Frazzoni, L.; Fuccio, L.; Serrani, M.; Cominardi, A.; Bazzoli, F.; Fusaroli, P. Repeat EUS-FNA of pancreatic masses after nondiagnostic or inconclusive results: Systematic review and meta-analysis. Gastrointest. Endosc. 2020, 91, 1234–1241.e4. [Google Scholar] [CrossRef] [PubMed]
  113. Han, S.; Bhullar, F.; Alaber, O.; Kamal, A.; Hopson, P.; Kanthasamy, K.; Coughlin, S.; Archibugi, L.; Thiruvengadam, N.; Moreau, C.; et al. Comparative diagnostic accuracy of EUS needles in solid pancreatic masses: A network meta-analysis. Endosc. Int. Open 2021, 9, E853–E862. [Google Scholar] [CrossRef] [PubMed]
  114. Facciorusso, A.; Chandan, S.; Gkolfakis, P.; Ramai, D.; Mohan, B.P.; Lisotti, A.; Bellocchi, M.C.C.; Papanikolaou, I.S.; Mangiavillano, B.; Triantafyllou, K.; et al. Do Biliary Stents Affect EUS-Guided Tissue Acquisition (EUS-TA) in Solid Pancreatic Lesions Determining Biliary Obstruction? A Literature Review with Meta-Analysis. Cancers 2023, 15, 1789. [Google Scholar] [CrossRef] [PubMed]
  115. Giri, S.; Afzalpurkar, S.; Angadi, S.; Varghese, J.; Sundaram, S. Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound–guided tissue acquisition from solid pancreatic lesions: A systematic review and meta-analysis. Clin. Endosc. 2023, 56, 169–179. [Google Scholar] [CrossRef] [PubMed]
  116. Chandan, S.; Mohan, B.P.; Khan, S.R.; Ofosu, A.; Dhaliwal, A.S.; Shah, A.R.; Bhogal, N.; Mashiana, H.S.; Mashiana, S.S.; Kassab, L.L.; et al. Comparison of EUS-guided conventional smear and liquid-based cytology in pancreatic lesions: A systematic review and meta-analysis. Endosc. Int. Open 2020, 8, E1611–E1622. [Google Scholar] [CrossRef]
  117. Chaiteerakij, R.; Prasoppokakorn, T.; Tiyarattanachai, T.; Decharatanachart, P.; Mekaroonkamol, P.; Ridtitid, W.; Kongkam, P.; Rerknimitr, R. Application of artificial intelligence for diagnosis of pancreatic ductal adenocarcinoma by EUS: A systematic review and meta-analysis. Endosc. Ultrasound 2022, 11, 17–26. [Google Scholar] [CrossRef] [PubMed]
  118. Dhali, A.; Kipkorir, V.; Srichawla, B.S.; Kumar, H.; Rathna, R.B.; Ongidi, I.; Chaudhry, T.; Morara, G.; Nurani, K.; Cheruto, D.; et al. Artificial intelligence assisted endoscopic ultrasound for detection of pancreatic space-occupying lesion: A systematic review and meta-analysis. Int. J. Surg. 2023, 109, 4298–4308. [Google Scholar] [CrossRef] [PubMed]
  119. Camus, B.; Pellat, A.; Rouquette, A.; Marchese, U.; Dohan, A.; Belle, A.; Ali, E.A.; Chaussade, S.; Coriat, R.; Barret, M. Diagnostic Yield of Repeat Endoscopic Ultrasound-Guided Fine Needle Biopsy for Solid Pancreatic Lesions. Cancers 2023, 15, 3745. [Google Scholar] [CrossRef]
  120. Cho, J.H.; Kim, J.; Lee, H.S.; Ryu, S.J.; Jang, S.I.; Kim, E.J.; Kang, H.; Lee, S.S.; Song, T.J.; Bang, S. Factors Influencing the Diagnostic Performance of Repeat Endoscopic Ultrasound-Guided Fine-Needle Aspiration/Biopsy after the First Inconclusive Diagnosis of Pancreatic Solid Lesions. Gut Liver 2023, 17. [Google Scholar] [CrossRef]
  121. Arya, N.; Wyse, J.; Jayaraman, S.; Ball, C.; Lam, E.; Paquin, S.; Lightfoot, P.; Sahai, A.V. A proposal for the ideal algorithm for the diagnosis, staging, and treatment of pancreas masses suspicious for pancreatic adenocarcinoma: Results of a working group of the Canadian Society for Endoscopic Ultrasound. Endosc Ultrasound. 2020, 9, 154–161. [Google Scholar]
  122. Nakai, Y.; Isayamam, H.; Wang, H.; Rerknimitr, R.; Khor, C.; Yasuda, I.; Kogure, H.; Moon, J.H.; Lau, J.; Lakhtakia, S.; et al. International consensus statements for endoscopic management of distal biliary stricture. J. Gastroenterol. Hepatol. 2020, 35, 967–979. [Google Scholar] [CrossRef] [PubMed]
  123. Cannon, M.E.; Carpenter, S.L.; Elta, G.H.; Nostrant, T.T.; Kochman, M.L.; Ginsberg, G.G.; Stotland, B.; Rosato, E.F.; Morris, J.B.; Eckhauser, F.; et al. EUS compared with CT, magnetic resonance imaging, and angiography and the influence of biliary stenting on staging accuracy of ampullary neoplasms. Gastrointest. Endosc. 1999, 50, 27–33. [Google Scholar] [CrossRef] [PubMed]
  124. Fusaroli, P.; Manta, R.; Fedeli, P.; Maltoni, S.; Grillo, A.; Giovannini, E.; Bucchi, L.; Caletti, G. The influence of endoscopic biliary stents on the accuracy of endoscopic ultrasound for pancreatic head cancer staging. Endoscopy 2007, 39, 813–817. [Google Scholar] [CrossRef]
  125. Chen, C.-H.; Tseng, L.-J.; Yang, C.-C.; Yeh, Y.-H. Preoperative evaluation of periampullary tumors by endoscopic sonography, transabdominal sonography, and computed tomography. J. Clin. Ultrasound 2001, 29, 313–321. [Google Scholar] [CrossRef] [PubMed]
  126. Rana, S.; Rana, A. Endoscopic ultrasound-guided tissue acquisition: Techniques and challenges. J. Cytol. 2019, 36, 1–7. [Google Scholar] [CrossRef] [PubMed]
  127. Park, J.S.; Lee, J.H.; Song, T.J.; Lee, J.S.; Jo, S.J.; Oh, D.W.; Song, K.B.; Hwang, D.W.; Park, D.H.; Lee, S.S.; et al. The impact of preoperative EUS-FNA for distal resectable pancreatic cancer: Is it really effective enough to take risks? Surg. Endosc. 2022, 36, 3192–3199. [Google Scholar] [CrossRef] [PubMed]
  128. Yane, K.; Kuwatani, M.; Yoshida, M.; Goto, T.; Matsumoto, R.; Ihara, H.; Okuda, T.; Taya, Y.; Ehira, N.; Kudo, T.; et al. Non-negligible rate of needle tract seeding after endoscopic ultrasound-guided fine-needle aspiration for patients undergoing distal pancreatectomy for pancreatic cancer. Dig. Endosc. 2020, 32, 801–811. [Google Scholar] [CrossRef] [PubMed]
  129. Masuda, S.; Koizumi, K.; Shionoya, K.; Jinushi, R.; Makazu, M.; Nishino, T.; Kimura, K.; Sumida, C.; Kubota, J.; Ichita, C.; et al. Comprehensive review on endoscopic ultrasound-guided tissue acquisition techniques for solid pancreatic tumor. World J. Gastroenterol. 2023, 29, 1863–1874. [Google Scholar] [CrossRef]
  130. Pishvaian, M.J.; Blais, E.M.; Brody, J.R.; Lyons, E.; DeArbeloa, P.; Hendifar, A.; Mikhail, S.; Chung, V.; Sahai, V.; Sohal, D.P.S.; et al. Overall survival in patients with pancreatic cancer receiving matched therapies following molecular profiling: A retrospective analysis of the Know Your Tumor registry trial. Lancet Oncol. 2020, 21, 508–518. [Google Scholar] [CrossRef]
  131. Imaoka, H.; Sasaki, M.; Hashimoto, Y.; Watanabe, K.; Miyazawa, S.; Shibuki, T.; Mitsunaga, S.; Ikeda, M. Impact of Endoscopic Ultrasound-Guided Tissue Acquisition on Decision-Making in Precision Medicine for Pancreatic Cancer: Beyond Diagnosis. Diagnostics 2021, 11, 1195. [Google Scholar] [CrossRef]
  132. Bang, J.Y.; Hebert-Magee, S.; Navaneethan, U.; Hasan, M.K.; Hawes, R.; Varadarajulu, S. EUS-guided fine needle biopsy of pancreatic masses can yield true histology. Gut 2018, 67, 2081–2084. [Google Scholar] [CrossRef]
  133. Sugimoto, M.; Irie, H.; Takagi, T.; Suzuki, R.; Konno, N.; Asama, H.; Sato, Y.; Nakamura, J.; Takasumi, M.; Hashimoto, M.; et al. Efficacy of EUS-guided FNB using a Franseen needle for tissue acquisition and microsatellite instability evaluation in unresectable pancreatic lesions. BMC Cancer 2020, 20, 1094. [Google Scholar] [CrossRef]
  134. Bang, J.Y.; Jhala, N.; Seth, A.; Krall, K.; Navaneethan, U.; Hawes, R.; Wilcox, C.M.; Varadarajulu, S. Standardisation of EUS-guided FNB technique for molecular profiling in pancreatic cancer: Results of a randomised trial. Gut 2023, 72, 1255–1257. [Google Scholar] [CrossRef] [PubMed]
  135. Zhang, M.-M.; Yang, H.; Jin, Z.-D.; Yu, J.-G.; Cai, Z.-Y.; Li, Z.-S. Differential diagnosis of pancreatic cancer from normal tissue with digital imaging processing and pattern recognition based on a support vector machine of EUS images. Gastrointest. Endosc. 2010, 72, 978–985. [Google Scholar] [CrossRef] [PubMed]
  136. Kurt, M.; Ozkan, M.; Cakiroglu, M.; Kocaman, O.; Yilmaz, B.; Can, G.; Korkmaz, U.; Dandil, E.; Eksi, Z. Age-based computer-aided diagnosis approach for pancreatic cancer on endoscopic ultrasound images. Endosc. Ultrasound 2016, 5, 101–107. [Google Scholar] [CrossRef] [PubMed]
  137. Goyal, H.; Sherazi, S.A.A.; Gupta, S.; Perisetti, A.; Achebe, I.; Ali, A.; Tharian, B.; Thosani, N.; Sharma, N.R. Application of artificial intelligence in diagnosis of pancreatic malignancies by endoscopic ultrasound: A systemic review. Ther. Adv. Gastroenterol. 2022, 15, 17562848221093873. [Google Scholar] [CrossRef] [PubMed]
  138. Săftoiu, A.; Vilmann, P.; Gorunescu, F.; Janssen, J.; Hocke, M.; Larsen, M.; Iglesias–Garcia, J.; Arcidiacono, P.; Will, U.; Giovannini, M.; et al. Efficacy of an Artificial Neural Network–Based Approach to Endoscopic Ultrasound Elastography in Diagnosis of Focal Pancreatic Masses. Clin. Gastroenterol. Hepatol. 2012, 10, 84–90.e1. [Google Scholar] [CrossRef] [PubMed]
  139. Li, Z.; Yin, H.; Yang, X.; Sun, L.; Pan, P.; Peng, L.; Li, K.; Zhang, D.; Cui, F.; Xia, C.; et al. The value of artificial intelligence techniques in predicting pancreatic ductal adenocarcinoma with EUS images: A meta-analysis and systematic review. Endosc. Ultrasound 2023, 12, 50–58. [Google Scholar] [CrossRef] [PubMed]
  140. Dumitrescu, E.A.; Ungureanu, B.S.; Cazacu, I.M.; Florescu, L.M.; Streba, L.; Croitoru, V.M.; Sur, D.; Croitoru, A.; Turcu-Stiolica, A.; Lungulescu, C.V. Diagnostic Value of Artificial Intelligence-Assisted Endoscopic Ultrasound for Pancreatic Cancer: A Systematic Review and Meta-Analysis. Diagnostics 2022, 12, 309. [Google Scholar] [CrossRef] [PubMed]
  141. Dahiya, D.S.; Al-Haddad, M.; Chandan, S.; Gangwani, M.K.; Aziz, M.; Mohan, B.P.; Ramai, D.; Canakis, A.; Bapaye, J.; Sharma, N. Artificial Intelligence in Endoscopic Ultrasound for Pancreatic Cancer: Where Are We Now and What Does the Future Entail? J. Clin. Med. 2022, 11, 7476. [Google Scholar] [CrossRef]
  142. Tong, T.; Zhang, C.; Li, J.; Deng, M.; Wang, X. Preclinical models derived from endoscopic ultrasound-guided tissue acquisition for individualized treatment of pancreatic ductal adenocarcinoma. Front. Med. 2023, 9, 934974. [Google Scholar] [CrossRef] [PubMed]
  143. Peschke, K.; Jakubowsky, H.; Schäfer, A.; Maurer, C.; Lange, S.; Orben, F.; Bernad, R.; Harder, F.N.; Eiber, M.; Öllinger, R.; et al. Identification of treatment-induced vulnerabilities in pancreatic cancer patients using functional model systems. EMBO Mol. Med. 2022, 14, e14876. [Google Scholar] [CrossRef]
  144. Demyan, L.; Habowski, A.N.; Plenker, D.; King, D.A.; Standring, O.J.; Tsang, C.B.; Surin, L.S.; Rishi, A.; Crawford, J.M.; Boyd, J.; et al. Pancreatic Cancer Patient-derived Organoids Can Predict Response to Neoadjuvant Chemotherapy. Ann. Surg. 2022, 276, 450–462. [Google Scholar] [CrossRef]
  145. Hogenson, T.L.; Xie, H.; Phillips, W.J.; Toruner, M.D.; Li, J.J.; Horn, I.P.; Kennedy, D.J.; Almada, L.L.; Marks, D.L.; Carr, R.M.; et al. Culture media composition influences patient-derived organoid ability to predict therapeutic responses in gastrointestinal cancers. J. Clin. Investig. 2022, 7, e158060. [Google Scholar] [CrossRef]
  146. Grützmeier, S.E.; Kovacevic, B.; Vilmann, P.; Rift, C.V.; Melchior, L.C.; Holmström, M.O.; Brink, L.; Hassan, H.; Karstensen, J.G.; Grossjohann, H.; et al. Validation of a Novel EUS-FNB-Derived Organoid Co-Culture System for Drug Screening in Patients with Pancreatic Cancer. Cancers 2023, 15, 3677. [Google Scholar] [CrossRef]
  147. Dornblaser, D.W.; Khamaysi, I.; Gross, S.A. Pilot study comparing a novel EUS-guided motorized biopsy needle technique with traditional sampling. iGIE 2023, 2, 126–130. [Google Scholar] [CrossRef]
Figure 1. Pancreatic ductal adenocarcinoma on EUS examination with different degrees of vascular involvement. (a) Hypoechoic irregular mass lesion in uncinate process that has clear non-invasion with surrounding vessels. (b) Hypoechoic irregular mass lesion near pancreatic head that is abutting SMV; however, fat planes within the vessel are still patent (white arrow). (c) Heterogenous hypo-isoechoic mass lesion in pancreatic head with loss of fat planes with splenic-portal confluence. (d) Hypoechoic mass lesion in pancreatic body completely encasing splenic artery.
Figure 1. Pancreatic ductal adenocarcinoma on EUS examination with different degrees of vascular involvement. (a) Hypoechoic irregular mass lesion in uncinate process that has clear non-invasion with surrounding vessels. (b) Hypoechoic irregular mass lesion near pancreatic head that is abutting SMV; however, fat planes within the vessel are still patent (white arrow). (c) Heterogenous hypo-isoechoic mass lesion in pancreatic head with loss of fat planes with splenic-portal confluence. (d) Hypoechoic mass lesion in pancreatic body completely encasing splenic artery.
Diagnostics 14 00078 g001
Figure 2. (a) Peri-vascular cuffing surrounding celiac axis (4.1 mm; green arrow) in a case of pancreatic adenocarcinoma. (b) Segment III hepatic lesion (green arrow) in a known case of pancreatic adenocarcinoma which was undetected in pre-procedure CT scan.
Figure 2. (a) Peri-vascular cuffing surrounding celiac axis (4.1 mm; green arrow) in a case of pancreatic adenocarcinoma. (b) Segment III hepatic lesion (green arrow) in a known case of pancreatic adenocarcinoma which was undetected in pre-procedure CT scan.
Diagnostics 14 00078 g002
Figure 3. Contrast-enhanced EUS using 4.8 mL of Sonozoid showing (a) early and iso-enhancement of the lesion (blue arrow points towards lesion and white arrow points towards surrounding pancreatic parenchyma) in a case of pancreatic neuroendocrine tumor. (b) Hypo-enhancement compared to surrounding pancreatic parenchyma (blue arrow points towards lesion and white arrow points towards surrounding pancreatic parenchyma) in a case of pancreatic adenocarcinoma.
Figure 3. Contrast-enhanced EUS using 4.8 mL of Sonozoid showing (a) early and iso-enhancement of the lesion (blue arrow points towards lesion and white arrow points towards surrounding pancreatic parenchyma) in a case of pancreatic neuroendocrine tumor. (b) Hypo-enhancement compared to surrounding pancreatic parenchyma (blue arrow points towards lesion and white arrow points towards surrounding pancreatic parenchyma) in a case of pancreatic adenocarcinoma.
Diagnostics 14 00078 g003
Figure 4. Strain elastography image showing (a) predominantly yellow-greenish hue (soft) with strain ratio of 4.71 in a case of chronic pancreatitis; (b) heterogenous blue hue (hard) with strain ratio of 52.35 in a known case of pancreatic adenocarcinoma (‘A’ is selected as the largest circumference of target lesion without involving intervening vessels and ‘B’ is selected as reference usually surrounding gastrointestinal wall).
Figure 4. Strain elastography image showing (a) predominantly yellow-greenish hue (soft) with strain ratio of 4.71 in a case of chronic pancreatitis; (b) heterogenous blue hue (hard) with strain ratio of 52.35 in a known case of pancreatic adenocarcinoma (‘A’ is selected as the largest circumference of target lesion without involving intervening vessels and ‘B’ is selected as reference usually surrounding gastrointestinal wall).
Diagnostics 14 00078 g004
Figure 5. Showing macroscopic visible core (MVC) (whitish bulky tissue fragments) (blue arrow) with individual fragment >4 mm in size and total segment size of 3.2 cm (obtained using 22G Acquire needle).
Figure 5. Showing macroscopic visible core (MVC) (whitish bulky tissue fragments) (blue arrow) with individual fragment >4 mm in size and total segment size of 3.2 cm (obtained using 22G Acquire needle).
Diagnostics 14 00078 g005
Table 1. EUS tissue acquisition needles.
Table 1. EUS tissue acquisition needles.
Type of Needle, Needle DesignProprietary Name, Needle DiameterManufacturer
EUS FNA needle
Menghini typeBeacon EUS Delivery system with BNX FNA preloaded needleBeacon Endoscopic, Newton, MA, USA
BNX FNA needle (without sheath)Beacon Endoscopic, Newton, MA, USA
Expect 19, 22, 25GBoston Scientific, Marlborough, MA, USA
Expect Flex 19GBoston Scientific, Marlborough, MA, USA
Expect Slimline 19, 22, 25GBoston Scientific, Marlborough, MA, USA
Expect Slimline Flex 19GBoston Scientific, Marlborough, MA, USA
ClearView 19, 22, 25GConmed, Billercia, MA, USA
ClearView Sheath Stabilizer 22, 25GConmed, Billercia, MA, USA
ClearView Extended Bevel 22GConmed, Billercia, MA, USA
SonoTip Pro Control 19, 22, 25GMediGlobe GmbH, Achenmühle, Germany
EchoTip Ultra 19, 22, 25GCook Medical, Bloomington, IN, USA
EchoTip Ultra coil sheath 22GCook Medical, Bloomington, IN, USA
EchoTip Ultra HD Access 19GCook Medical, Bloomington, IN, USA
EZ shot 2 19, 22, 25GOlympus America, Center Valley, PA, USA
EZ shot 2 sideport 22GOlympus America, Center Valley, PA, USA
EZ shot 3 plus 19, 22GOlympus America, Center Valley, PA, USA
EUS Sonopsy CY™ 21GHakko Co., Tokyo, Japan
EUS FNB needles
Forward-bevelEchotip Procore 20GCook Medical, Bloomington, IN, USA
Reverse-bevelEchotip Procore 19, 22, 25GCook Medical, Bloomington, IN, USA
Fork-tipSharkCore 19, 22, 25GMedtronic, Dublin, Ireland
Beacon EUS delivery system with SharkCore preloaded FNB needle 19, 22, 25GMedtronic, Dublin, Ireland
FranseenAcquire 19, 22, 25GBoston Scientific, Marlborough, MA, USA
Sonotip Topgain 19, 22, 25GMediglobe, Achenmühle, Germany
Abbreviations: EUS: Endoscopic ultrasound, FNA: Fine-needle aspiration; FNB: Fine-needle biopsy.
Table 2. Summary of recent meta-analysis of diagnostic EUS in pancreatic cancer.
Table 2. Summary of recent meta-analysis of diagnostic EUS in pancreatic cancer.
SRMA (Author, year)Number of Studies and Total Number of Patients (n)Modality/ComparisonType of LesionMain Outcome MeasureSensitivity (%)Specificity (%)PPVNPVAdequacy (%)Accuracy (%)Contamination (%)Other Parameters (%)Adverse Events (%)
Role of Diagnostic EUS
Rahman MIO et al., 2020 [96]2 studies, n = 77EUS vs. CECT in pancreatic protocolNeoplastic pancreatic lesionsDiagnostic accuracy for pancreatic cancer resectability8763-----Similar diagnostic OR (p > 0.05)-
Krishna SG et al., 2017 [14]4 studiesEUS after an indeterminate MDCTSuspected pancreatic malignanciesDiagnostic performance for detection of pancreatic malignancies85587766-75---
Li Y et al., 2019 [97]16 studies, n = 1325CE EUS for pancreatic massesPancreatic massesDiagnostic performance of CE EUS for the differentiation of pancreatic masses9384-----LR+ 5.58
LR− 0.09
DOR 72.5%
-
Yamashita Y et al., 2019 [98]9 studies, n = 887CE EUSPancreatic cancerDiagnostic performance for diagnosing pancreatic cancer9380-----LR+ 4.56
LR− 0.09
DOR 59.89
-
Shin CM et al., 2023 [99]6 studies, n = 430Combined CE EUS and EUS elastography in solid pancreatic lesionsSolid pancreatic lesionsDiagnostic performance in detecting pancreatic malignancies8485-----LR+ 5.31
LR− 0.15
DOR 67.72
-
Facciorusso A et al., 2021 [100]6 studies, n = 701CE EUS-guided vs. standard EUS FNA in pancreatic massesSolid pancreatic lesionsDiagnostic outcome84.6 vs. 75.3 (p < 0.001)100% both--95.1 vs. 89.4 (p = 0.02)88.8 vs. 83.6 (p = 0.05)-Histological core procurement p = 0.08, number of needle passes p = 0.29-
EUS tissue acquisition (EUS TA)
Banafea O et al., 2016 [101]20 studies, n = 2761EUS FNBPancreatic massDiagnsotic accuracy90.896.5---91-LR+ 14.8
LR− 0.12
DOR 142.47
35 of 1760 patients in 15 studies
Guedes HG et al., 2018 [56]4 studies, n = 50422G versus 25G needles in EUS FNB for solid pancreatic mass
Solid pancreatic massesDiagnostic performance91 vs. 93
p>0.05
83 vs. 87
p>0.05
-----LR+ 4.26 vs. 4.57
LR− 0.13 vs. 0.08
p > 0.05
-
Xu MM et al. [102]11 studies, n = 83722G vs. 25G EUS FNA needleSolid pancreatic lesionsDiagnostic performance88 vs. 92
p = 0.046
100 vs. 100
p = 0.842
-----LR+ 12.61 vs. 8.44
LR− 0.16 vs. 0.13
AUSROC 0.97 vs. 0.96
-
Tian G et al., 2018 [103]16 studies, n = 182422G vs. 25G EUS FNA needleMasses with suspicion of pancreatic cancerDiagnostic yield for the detection of pancreatic cancer89 vs. 90
p = 0.02
100 vs. 99
p = 0.15
-----LR+ 485.28 vs. 59.53
LR− 0.11 vs. 0.10
AUROC 0.97 for both
-
Yang Y et al., 2016 [104]16 studies, n = 828EUS FNBSolid malignant pancreatic lesionsDiagnostic accuracy8498 LR+ 8
LR− 0.17
DOR 64
AUROC 0.96
-
Reneleus et al., 2021
[63]
11 studies, n = 1365EUS FNB vs. FNASolid pancreatic lesionsDiagnostic accuracy and safety-----Diagnostic accuracy of 87 vs. 81 (p = 0.005).
Cytopathological accuracy of 89 vs. 82 (p = 0.04).
Histological accuracy of 81 vs. 74 (p = 0.39)
-Mean TSR was 99% in both.
Mean needle passes required for adequate tissue was 2.3 vs. 1.6 (mean difference was 0.71) (p < 0.0001)
2.3 vs. 1.8 (p = 0.64)
van Riet PA et al., 2021 [62]18 RCTs, n = 2695EUS FNB vs. FNA for samplingSolid pancreatic and non-pancreatic lesionsDiagnostic accuracy, adequacy, number of passes, presence of tissue cores, and adverse events----90 vs. 88 (p = 0.76)85 vs. 80 (p = 0.03)
High-quality studies 82 vs. 74 (p = 0.002)
-Mean number of passes was lower in FNB (mean difference −0.54) p = 0.03.
Presence of tissue cores: 79 vs. 63 (p = 0.11)
0.8 vs. 1.0 (p = 0.8)
Hassan GM et al., 2022 [105]9 RCTs, n NAEUS FNB vs. EUS FNASolid pancreatic massesDiagnostic accuracy for the diagnosis of pancreatic cancer-----FNB had a superior accuracy compared to FNA (OR 1.87)---
Bang JY et al., 2016 [106]9 studies, n = 576Procore vs. standard EUS FNA needle in solid lesionsAll solid lesionsDiagnostic adequacy, diagnostic accuracy, acquisition of histological core tissue, and mean number of passes----75.2 vs. 89.0; OR 0.39 (p = 0.23)85.8 vs. 86.2; OR 0.88 (p = 0.53)-Rate of histological core specimen acquisition (77.7% vs. 76.5%; OR 0.94, p = 0.85).
Lower mean number of passes required for diagnosis with the ProCore needle (SMD—1.2, p < 0.001).
-
Li Z et al., 2022 [107]18 studies, n = 2718EUS FNB vs. EUS FNBPancreatic and non-pancreatic solid lesions (only solid pancreatic lesions are mentioned in the subgroup analysis)Diagnostic accuracy, number of needle passes, adequacy, presence of tissue cores, and adverse events----FNB had a higher adequacy (RR = 0.93) p = 0.004Similar pooled accuracy (RR = 0.97) p = 0.13-Fewer number of passes for adequate sampling in FNB group (MD 0.57) p < 0.00001.
Presence of tissue core was similar (RR 0.60) p = 0.16
Similar (RR 1.27) p = 0.97
Facciorusso A et al., 2020 [108]11 trials, 833 patients22G FNB vs. 22G FNA needleSolid pancreatic lesionsDiagnostic outcome and tissue adequacy93.1 vs. 90.4100 in both--Slightly in favour of FNB (p = 0.61)--No difference in histological core procurement (p = 0.86).
Similar number of passes in FNB (MD -0.32, p = 0.07)
Six adverse events in FNA group and one in FNB group reported
Gkolfakis P et al., 2022 [69]RCT 16, n = 1934Different FNB needlesSolid pancreatic massesDiagnostic accuracy (network meta-analysis)94.6% with Franseen needle, 93.9% with Fork-tip needle, 90.4% with Menghini-tip needle, 82% with reverse-bevel needle, and 87.4% with FNA needlePooled specificity 100% with all needles tested--Franseen needle was better than FNA and reverse-beveled needles.
Fork-tip needles were superior to reverse-beveled needle.
None was superior when compared to FNA with ROSE.
Both 22G and 25G Franseen needles followed by the 22G fork-tip needle showed the highest SUCRA scores concerning sample adequacy
Franseen needle was better than FNA and reverse-beveled needles.
Fork-tip needles were superior to reverse-beveled needle.
None was superior when compared to FNA with ROSE.
The 22G Franseen needle ranked as the best FNB needle in terms of diagnostic accuracy (SUCRA score of 0.81)
--Pooled rate was 2.7% with Franseen needle; 2% with Fork-tip needle; 1.3% with Menghini-tip needle; 0.8% with reverse-bevel needle, and 1.9% with the FNA needle.
Facciorusso A et al., 2019 [109]24 studies, n = 6641Franseen vs. fork-tip EUS FNB needlesPancreatic and non-pancreatic solid lesions (only solid pancreatic lesions are mentioned in the subgroup analysis)Sample adequacySimilar sensitivity (95.3 vs. 93.4)Similar specificity [100]--97 vs. 92.6 (p = 0.006)96.8 vs. 95.2 (p = 0.8)-Histological core procurement was 94 vs. 93.1 (p = 0.7).
Fewer number of passes compared to standard FNA needles
(MD for Franseen was -0.44 and for Fork-tip was −1.82)
-
Facciorusso A et al., 2022 [110]8 studies, n = 2147EUS FNB with and without ROSESolid pancreatic lesionsSample adequacy94.3 vs. 91.5---EUS FNB with ROSE is not superior to EUS FNB alone (95.5 vs. 88.9, p = 0.07) especially when end-cutting needles (compared to reverse-bevel needles) are usedSuperior in the EUS FNB + ROSE group (OR = 2.49, p = 0.03)Number of needle passes needed to obtain diagnostic samples was not significantly different (mean difference 0.07; p = 0.62)-Only one study reported (Crino et al.)
Kong F et al., 2016 [111]7 studies, n = 1299EUS FNB with ROSE vs. EUS FNB without ROSEPancreatic massesDiagnostic adequacy, yield, number of needle passes, pooled sensitivity, and specificity91 vs. 85100 in both--No significant difference in cytological adequacyNo significant difference in diagnostic yield-LR+ 28.15 vs. 29.08
LR− 0.1 vs. 0.16.
Fewer needle passes in ROSE group (4 vs. 7, p < 0.0001)
-
Lisotti A et al., 2020 [112]12 studies, n = 505Repeat EUS FNB for the diagnosis of solid pancreatic massesSolid pancreatic massesDiagnostic performance of repeat EUS FNB in case of negative or inconclusive first FNA77 (83% with ROSE)989961---LR+ 38.9
LR− 0.23
-
Han S et al., 2021 [113]26 studies, n = 3398 (in primary NMA)Various EUS TA needlesSolid pancreatic massesDiagnostic accuracy compared to 22G Echotip (Cook) EUS FNA needle (NMA)-----Performance score-wise:
22 G SharkCore FNB needle (Medtronic) > 22G EZ Shot 3 FNB needle (Olympus) > 22G Acquire FNB needle (Boston Scientific)
-Diagnostic accuracy was not significantly different between needles with or without suction except 20G FNB needle with suction which performed significantly worse than the 22G FNA needle with suction-
Suction Techniques in EUS TA
Facciorusso A et al., 2023 [42]9 RCTs, n = 756Various EUS FNB techniquesSolid pancreatic massesRates of sample adequacy, blood contamination, and tissue integrity (NMA)Modified wet suction was most sensitive (SUCRA score, 0.85) followed by slow-pull techniques and no stylet technique (SUCRA scores, 0.66 and 0.48, respectively)---Modified wet-suction technique was best for adequacy (SUCRA score of 0.90) followed by dry-suction and slow-pull techniques (SUCRA scores of 0.59 and 0.50, respectively)-Higher level of blood contamination seen with dry-suction than slow-pull technique;
no-suction technique ranked as the best strategy (SUCRA score of 0.99) followed by the slow-pull technique (SUCRA score of 0.65).
Modified wet-suction (SUCRA score of 0.32) and dry-suction (SUCRA score of 0.12) techniques showed poor performance in terms of blood contamination of the sample
Regarding tissue integrity, modified wet-suction technique was ranked as the best strategy (SUCRA score of 0.89) followed by slow-pull (SUCRA score of 0.66) and no-suction (SUCRA score of 0.42) techniquesUncommon and usually mild, without significant impact on patient outcomes
(abdominal pain and bleeding)
Ramai D et al., 2021 [76]6 studies, n = 418Wet vs. dry suction techniquesSolid pancreatic massesAdequacy, sample contamination, and histological accuracy----Wet-suction technique has superior tissue adequacy (pooled adequacy rate of 91.9 vs. 77.32 (OR 3.18, p < 0.001))Wet-suction technique is superior in histological diagnosis (OR of 3.68, pooled rate of 84.06 vs. 68.87, p < 0.001). Wet suction has superior sample quality, and accuracyWet-suction technique has comparable blood contamination (OR of 1.18, contamination rate of 58.33 and 54.6, p = 0.256)--
Giri S et al., 2023 [81]7 studies, n = 2048Various suction techniques in EUS TASolid pancreatic and non-pancreatic lesionsCompare the diagnostic yields during EUS TA (NMA)----There was no difference between the various modalities. For the SUCRA analysis, WS > SSP > DS > NSNo significant difference in ORs of adequacy when adjusted for either of the needle types. For the SUCRA analysis, WS > NS > DS > SSPWhen adjusting for FNA needle, there was no difference between the interventionsNo significant difference between the studies with respect to moderate-to-high cellularity of samples-
EUS TA in Presence of Biliary Stents
Facciorusso A et al., 2023 [114]7 studies, n = 2458EUS TA in presence and absence of biliary stentSolid pancreatic head massesDiagnostic accuracy before and after biliary stenting in jaundiced patients with pancreatic head massesOverall diagnostic sensitivity lower in biliary stent group (82.9 vs. 87.5; OR 0.59; p < 0.001); in SEMS subgroup (p = 0.006) but not in plastic stent group (p = 0.12)---No significant difference in adequacy (p = 0.81)No overall significant difference 85.4 vs. 88.1 (p = 0.07).
No significant difference in plastic stent vs. no stent (p = 0.67).
Significant difference in SEMS vs. no SEMS (p = 0.05)
-No significant difference in number of needle passes (p = 0.38)No significant difference (p = 0.75)
Giri S et al., 2023 [115]9 studies, n = 3257EUS TA in presence and absence of biliary stentPancreatic masses undergoing EUS TADiagnostic accuracy of EUS TA in presence and absence of biliary stent79 vs. 88; Using non-strict criteria in patients with stents, the sensitivity was lower with metal stents than with plastic stents (83% vs. 90%)---Comparable in stent vs. non-stent groups and in plastic and SEMS groupLower accuracy with stent (OR of 0.58)
using non-strict criteria and comparable sensitivity between metal stents and plastic stents
-Patients with stents required greater number of passes (MD = 0.31)-
Advances of EUS
Chandan S et al., 2020 [116]9 studies, n = 1308EUS-guided precipitation-based LBC conventional smearSolid pancreatic massesDiagnostic yield of EUS-guided conventional smear vs. LBCPrecipitation based LBC higher sensitivity (85.2 vs. 79.7)Precipitation based LBC comparable specificity (99.5 vs. 99.4)Precipitation based LBC comparable PPV (99.5 in both)NPV was found to be higher with filtration-based LBC technique (50.9%) as compared with CS (46.2%) and precipitation-based LBC techniques (35.4%).-Precipitation-based LBC had a higher accuracy---
Prasoppokakorn T et al., 2021 [117]8 studies, n = 870AI-assisted diagnosis of PDAC by EUSPancreatic massAI-assisted B-mode EUS sensitivity and specificity 90%, 91% respectively.
AI-assisted CE EUS sensitivity and specificity 95%, 95% respectively.
AI-assisted EUS elastography sensitivity and specificity 88%, 83% respectively.
AI-assisted EUS 91%
AI-assisted B-mode EUS 91%
AI-assisted EUS 90%
AI-assisted B-mode EUS 90%
AI-assisted B-mode EUS 94%AI-assisted B-mode EUS 84%-----
Dhali A et al., 2023 [118]21 studiesAI-assisted vs. conventional EUS for detection of pancreatic SoLsDiagnostic performanceHigher accuracy of AI-assisted EUS for detection and differentiation93.993.191.693.6-93.6---
Abbreviations: PDAC—Pancreatic ductal adenocarcinoma; EUS—Endoscopic ultrasound; CE EUS—Contrast-enhanced EUS; EUS TA—EUS-guided tissue acquisition; FNA—Fine-needle aspiration; FNB—Fine-needle biopsy; LBC—Liquid-based cytology; CS—Conventional smear; ROSE—Rapid on-site cytology evaluation; MOSE—Macroscopic on-site cytology evaluation; SEMS—Self-expanding metal stent; WS—Wet-suction method; SSP—Stylate slow-pull method; DS—Dry-suction method; AI: Artificial intelligence; PPV—Positive predictive value; NPV—Negative predictive value; OR—Odd’s ratio; RR—Relative risk; AUROC—Area under receiver operating curve; NMA—Network meta-analysis; LR—Likelihood ratio.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Chatterjee, A.; Shah, J. Role of Endoscopic Ultrasound in Diagnosis of Pancreatic Ductal Adenocarcinoma. Diagnostics 2024, 14, 78. https://doi.org/10.3390/diagnostics14010078

AMA Style

Chatterjee A, Shah J. Role of Endoscopic Ultrasound in Diagnosis of Pancreatic Ductal Adenocarcinoma. Diagnostics. 2024; 14(1):78. https://doi.org/10.3390/diagnostics14010078

Chicago/Turabian Style

Chatterjee, Abhirup, and Jimil Shah. 2024. "Role of Endoscopic Ultrasound in Diagnosis of Pancreatic Ductal Adenocarcinoma" Diagnostics 14, no. 1: 78. https://doi.org/10.3390/diagnostics14010078

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop